Note 2: Use the startup, braking and other conditions of the simple graph operation, operate as normal unless special
instructions have been shown.
Note 3: For operating direction specified in T1~T15, when the rotation direction is fixed according to the allowable
direction of the motor, the use of an operation timer with an unallowed direction will lead the inverter into
standby and wait for the startup of the next timer.
Note 4: During simple graph operation, since the acceleration/deceleration time is specified by each timer, the switching
of acceleration/deceleration time by multi-functional input terminals AD2 and AD3 are noneffective.
4) Each timer operated with simple graph operation
When the simple graph operation is started with rotation direction specified by function codes and acceleration/deceleration
time according to the forward run command, T1~T15 as well as T0 will start to count by sequence. After a specified time
period, it will move to the next timer. This operation timer will start from T1 and continue to T2, T3...T15, T0 by sequence.
However, when the time of the operation timer is 0s, the current timer will be skipped and continue to the next timer.
F2203
Operation timer T1
F2204
Operation timer T2
Operation timer T3
F2205
F2206
Operation timer T4
Operation timer T5
F2207
F2208
Operation timer T6
F2209
Operation timer T7
Operation timer T8
F2210
F2211
Operation timer T9
F2212
Operation timer T10
F2213
Operation timer T11
F2214
Operation timer T12
Operation timer T13
F2215
F2216
Operation timer T14
F2217
Operation timer T15
Please set each expected time in the following function codes.
Code No.
Function Name
F2203
Operation timer T1
F2204
Operation timer T2
F2205
Operation timer T3
F2206
Operation timer T4
F2207
Operation timer T5
F2208
Operation timer T6
F2209
Operation timer T7
F2210
Operation timer T8
F2211
Operation timer T9
F2212
Operation timer T10
F2213
Operation timer T11
F2214
Operation timer T12
F2215
Operation timer T13
F2216
Operation timer T14
F2217
Operation timer T15
Note: When a timer is changed during operation, the value will be effective from the next cycle. If the change is made
after the operation, the value will become effective since the cycle is started.
F2218
Operation stop time T0
5) About the operation stop time T0
During simple graph operation, besides the above-mentioned T1~T15, there is an operation stop time T0 (F2218).
Each timer in simple operation is used as a cycle, but the cycle switching (i.e. moving from T15 to T1) after one complete
Data Content
0~65000 秒
- 119 -
7-3 Description of Functions
Setting Resolution
Factory Presets
10
1 秒