should be accorded to the deceleration time of midway stop deceleration time (F2219). F2219 will make a choice from 1
deceleration time to 4
F2219
Midway stop deceleration time
Midway start acceleration time
F2220
Code No.
Function Name
F2219
Midway stop deceleration time
F2220
Midway start acceleration time
Note: When stop command (or idle running) enters into the inverter, the current operation timer will be maintained, and
prepared for the next operation. When the operation command enters again, the operation timer will continue to work if
original frequency is reached.
·
During midway stop, if the conditions for another start are satisfied, the inverter will start acceleration to the original frequency
set in the operation timer and enters into the midway start status. The acceleration time of this period is accorded to the
acceleration time of midway start acceleration time (F2220).
·
F2219 can make a choice from 1
reached, the operation timer will work again.
Reference: During midway stop, even if the power supply is cut off, it still can record the last status of operation timer, therefore,
when daily operation is finished and the inverter is stopped or the power supply is cut off, the operation on the next day will continue
with the last operation.
Operation command
10) Resetting of simple operation timer during midway stop
·
Keep the timer running during midway stop. Therefore, when conditions for another start are satisfied, the inverter will
start acceleration to the original frequency set in the operation timer and continues with the remaining simple graph
operation. If the maintained status of the operation timer is not used, please use the reset functions on the control circuit
terminals to reset the operation timer.
·
Since the reset function has reset the total timers in simple graph operation, the next operation will start the cycle from
timer 1.
11) Setting & resetting method
·
Please use the resetting of simple graph operation timers (any one of F1414~F1421 equals to 37) to set the multi-function
input terminals.
·
If the inverter stays in stop status because of midway stop, please short-circuit the control circuit terminal and DCM1 or
DCM2 for over 100msec. Therefore rest the simple graph operation timer.
·
When the inverter is fully stopped because of midway stop, please reset the operation timer before the input of the next
operation signal. When inverter is during running, standby and start acceleration, even the reset of the timer is noneffective.
Note: If reset command of operation timer is input continuously, even when the next status is in midway stop state, the timer
can still reset. Please input reset command only when necessary.
th
deceleration time of F1016~F1019.
st
1: 1
deceleration time (value of F1016)
nd
2: 2
deceleration time (value of F1017)
rd
3: 3
deceleration time (value of F1018)
th
4: 4
deceleration time (value of F1019)
st
1: 1
acceleration time (value of F1012)
nd
2: 2
acceleration time (value of F1013)
rd
3: 3
acceleration time (value of F1014)
th
4: 4
acceleration time (value of F1015)
st
deceleration time to 4
Data Content
th
deceleration time of F1012~F1015. When the pre-set frequency is
Operation timer stops
Midway stop deceleration
Midway stop
Original T4 time
- 122 -
Setting Resolution
Factory Presets
1
1
Midway start acceleration
Time
时间
st
1
1