Current output multiple may be changed in function code F1515, please make appropriate adjustment based on service condition.
*
Adjust the maximum output frequency to 20mA or below.
Adjust the impedance of current output load side to 500Ω or below. In case of large impedance, the current output shall be 20mA or
below.
When the current output makes output frequency=0 Hz, multiple=0, please output the minimum value 4mA.
Make sure that there is no wiring short-circuit and open circuit at load side before current output.
The signal wire may not work correctly due to short-circuit or open circuit.
F1516
Torque matching level
Torque matching range
F1517
These functions are used to set torque level and torque matching range output by the torque matching signal. This function is active in
vector control mode.
Code No.
Function Name
F1516
Torque matching level
Code No.
Function Name
F1517
Torque matching range
If any one of F1509 – F1511 is 42 (frequency matching signal), the signal is output from control circuit output terminals DO1 to DO3
when the output torque matches the set value. The matching range is specified with the set value of F1517. Similarly, for F1513, the
signal can also be output from control circuit relay output terminals FA1, FB1 or FC1.
F1518
Low speed matching level
F1519
Low speed matching range
These functions are used to set torque level and torque matching range output by the torque matching signal.
Code No.
Function Name
F1518
Low speed matching level
Code No.
Function Name
F1519
Low speed matching range
If any one of F1509 – F1511 is 43 (low speed detection signal), the signal is output from control circuit output terminals DO1 to DO3
when the detected speed matches the value set by F1518. The matching width is specified with the set value of F1519. Similarly, for
F1513, the signal can also be output from control circuit relay output terminals FA1, FB1 or FC1.
The low speed matching range is also used in forward run detection signal or reverse run detection signal for multifunctional output.
Current
Output
[mA]
Inverter output frequency [Hz]
Current output multiple F1515
Data Content
0~±200%
Data Content
Data Content
0~2000rpm
Data Content
0~100rpm
- 99 -
×
Setting Resolution
Setting Resolution
0~50%
Setting Resolution
Setting Resolution
Factory Presets
0.1%
100
Factory Presets
0.1%
25
Factory Presets
1rpm
100
Factory Presets
1rpm
10