Sanken S06-4A005-B Instruction Manual page 145

High performance vector control multifunction inverter
Table of Contents

Advertisement

Please set the value with 1-254. Pay attention not to repeat with other inverter numbers. It is not required to set the number
sequentially, a loss of number is allowable.
Note 1: When setting a repetitive number, it cannot ensure a normal communication.
Note 2: In dedicated protocol communication, number 1-32 is effective.
F4007
Communication speed
The function to set communication speed.
Code No.
Function Name
F4007
Communication speed
F4008
Parity bit
The function to set the parity bit.
Code No.
Function Name
F4008
Parity bit
F4009
Stop bit
The function to set the stop bit.
Code No.
Function Name
F4009
Stop bit
F4010
End bit
The function to set the end code for dedicated protocol communication function.
Code No.
Function Name
F4010
End bit
F4011
Inverter's response to specified commands
The function to limit the response message sent from the inverter to specified command, therefore increase the communication speed.
Code No.
Function Name
F4011
Inverter's response to specified
commands
ModBus communication timeout setting
F4101
The function to set ModBus communication timeouts time.
Code No.
Function Name
F4101
ModBus communication timeout setting
During ModBus communication, if no message has been received within the time period set by F4101, it will be considered as
communication timeouts.
F4102
ModBus communication timeout action
The function to select ModBus communication timeout action.
Code No.
Function Name
Data Content
1: 1200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
6: 38400bps
7: 57600bps
Data Content
No
0:
Odd
1:
Even
2:
Data Content
1:
1 bit
2 bits
2:
Data Content
0:CR+LF
1:CR
Data Content
0:
Sent
Not sent (Error response sent)
1:
Not sent (No error response sent)
2:
Data Content
0:No function
sec.
0.01~600
Data Content
- 144 -
Factory
Setting Resolution
Presets
1
4
Factory
Setting Resolution
Presets
1
1
Factory
Setting Resolution
Presets
1
1
Factory
Setting Resolution
Presets
1
0
Factory
Setting Resolution
Presets
1
0
Factory
Setting Resolution
Presets
0.01
s
Setting Resolution
Factory