Sanken S06-4A005-B Instruction Manual page 48

High performance vector control multifunction inverter
Table of Contents

Advertisement

1110
Direction of rotation
of motor
1111
Braking method
1112
DC braking start
frequency
1113
DC braking time
1114
DC braking force
1115
Duty cycle of brake
resistor
1116
Discharge resistor on
signal output
time
1201
Monitor display
selection
1202
State display selection
1203
Multiple for no-units
display
1301
1st jump bottom
frequency
1302
1st jump top frequency
1303
2nd jump bottom
frequency
1304
2nd jump top
frequency
1305
3rd jump bottom
frequency
1306
3rd jump top
frequency
1307
Auto alarm recovery
1308
Instability elimination
1309
Operation direction
switching in V / f
control mode
1315
Shortest operation
time function
1316
2nd Upper frequency
limit
1317
3rd Upper frequency
limit
1318
Cooling fan ON/OFF
control
1319
Functions
corresponding to high
altitude areas
1320
Rating selection
1: Forward run
2: Reverse run
1: Deceleration to stop
2: Deceleration to stop + DC braking
3: Free run stop
0.05-20Hz
0.1 -10 sec.
1-10
0: No brake resistor
2-25%ED
98: No discharge resistor protection
(with discharge)
99: External brake unit
0.01 -10.00 sec.
1: Frequency [Hz]
2: Output current (A)
3: Speed of rotation [rpm]
4: Load factor [%]
5:voltage[V]
6:压力[MPa]
7:No unit display
1: No units (multiple of F1203)
2: Output voltage [V]
3: DC voltage [V]
4: Active power [kW]
5: Apparent power [kVA]
6: Radiator temperature [ ]
7: Command speed [rpm]
8: PID1 feedback value [Hz]
9: PID2 feedback value [Hz]
10: VRF1 analog input value [Hz]
11: VRF/IRF analog input value [Hz]
12: Reserved
13: Output torque [%]
14: Partial excitation current [A]
15: Partial torque current [A]
16: Detecting position [mm]
29: Command frequency [Hz]
30: Command torque [%]
35: Reserved
44:target frequency[HZ]
45:output frequency[HZ]
0-100
(multiple of the output frequency)
0~400 [Hz]
0~400 [Hz]
0~400 [Hz]
0~400 [Hz]
0~400 [Hz]
0~400 [Hz]
0: No auto reset function
1: Auto reset function
0~20
0: Start from the direction opposite to current
direction after a stop
1: Continuous operation
0 -99.99 sec.
5-590 [Hz]
5-590 [Hz]
0: ON/OFF control
1: Normally ON
1: 1,000m or below
2: 1,000m-1,500m or below
3: 1,500m-2,000m or below
4: 2,000m-2,500m or below
5:2,500m-3,000m
1: Mode A (heavy load mode) 150% 1 minute
- 47 -
1
1
1
1
0.01Hz
0.5
0.1 s
2
1
5
1%ED
1
0.01 s
0.1
1
1
1
1
1
0.01 倍
0.01 [Hz]
0
0.01 [Hz]
0
0.01 [Hz]
0
0.01 [Hz]
0
0.01 [Hz]
0
0.01 [Hz]
0
1
0
1
0
1
0
0.01 s
0
0.01 [Hz]
60
0.01 [Hz]
60
1
0
1
1
1
2