7-3
Description of Functions
rd
Example 1) When 3
speed is selected, the frequency set by operation panel will be stored in F2103.
Example 2) During the halfway of changing the frequency of 3
speed switched to 5
● External terminals are other functions and multiplexed functions.
Example) 67:2DF+AD2
For these multiplexed terminals, the information for multi-speed operation will be only used as the terminal status of 2DF, AD2
status has no relationship with the multi-speed operation. For multi-speed switching of external terminals and the operation status
of inverter as well as F1101: when the content selected by operation command has no relationship, it is effective.
Code No.
F2101
F2102
F2103
F2104
F2105
F2106
F2107
F2108
F2109
F2110
F2111
F2112
F2113
F2114
F2115
F2116
Graph Operation Function
Simple scheduled operation function (F2201=1)
Selection of Scheduled operation
F2201
F2202
Simple scheduled operation repetitions
The function to select an operation mode.
Code No.
Function Name
F2201
Selection of Scheduled
operation
F2202
Simple scheduled operation
repetitions
● The function to establish a graph with the function codes for auto operation of running direction, set frequency, operation time,
acceleration/ deceleration time and so on. This can be used effectively during setting the operating graph of auto operation.
● The operating graph including stopping timer can be set into 16 graphs. Furthermore, the total 16 graphs can be operated as one
cycle, also it can be operate repeatedly within the specified times. Since the operating status will be stored in the memory during
power failure, the inverter will continue the interrupted graph when it is returned to normal operation.
1) Use control terminals on inverter
Control Terminal
DI1~DI8※
DO1~DO3※
COM1、COM2
*Please select the terminals through the function codes and set the contents.
2) Startup of simple scheduled operation
Please set F2201=1 (simple scheduled operation). When motor control mode is V/f or speed control, the simple scheduled
operation is effective.
The operating command is only effective for operation panel, external control circuit terminal and other forward run, so
please input forward run command which has no relationship with the operation direction.
The operation direction and acceleration/deceleration time can be set by the 16 timers from T1 to T16.
th
th
speed will change to 5
Frequency
2DF
1st speed
OFF
2nd speed
ON
3rd speed
OFF
4th speed
ON
OFF
5
th speed
th speed
ON
6
th speed
OFF
7
th speed
ON
8
th speed
OFF
9
th speed
ON
10
th speed
OFF
11
th speed
ON
12
th speed
OFF
13
14
th speed
ON
th speed
OFF
15
16
th speed
ON
Normal operation
0:
1:
Simple scheduled operation
Disturbed operation
2:
Continuous
0:
Repetition count
1~250:
Content
Timer reset function
Cycle completion signal
Digital signal public
terminal
rd
speed operation, the output frequency of the inverter with the
speed. However, the set frequency is 3
3DF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Data Content
Function Code Setting
F1414~F1421
F1509~F1511
- 117 -
rd
speed frequency (F2103).
5DF
9DF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
Setting Resolution
Factory Presets
1
0
1
1
37
3