Sanken S06-4A005-B Instruction Manual page 172

High performance vector control multifunction inverter
Table of Contents

Advertisement

IN
Inverter No.
OP
Command code
DT
Setting data
④⑤
SUM
Checksum
Reference 2: As an example of checksum calculation for BINARY format, set 50.00 Hz on the first inverter
①Start code
②Inverter No.
③Command
④Data (upper byte)
⑤Data (lower byte)
⑥Sum of ①~⑤
⑦Lower byte of 12BH
⑧ 2's complement of 2BH
⑵ Details of message formation
① ASCⅡ-format message
OP—CD
Transmission from computer to inverter
A
·
Reading of alarm number
HD
IN
*
0
B
·
Reading of function code
·
F4006 Inverter number
HD
IN
OP
*
0 1
B
C
·
Reading of output frequency
HD
IN
*
0
D
·
Reading of output current
HD
IN
*
0
E
·
Reading of DC voltage
HD
IN
*
0
Inverter number at receiving end
Example: 14H for inverter number of 20
Inverter command code
Data sent into inverter
Example: For data 123
④→00H ⑤→7BH
※Added only to a command code when there is applicable setting data.
Add the two's complement of the lower byte of the BINARY sum of data ①-⑤.
(See Reference 2)
=40H :
=01H
=4FH :
=13H :
=88H :
=12BH:
=2BH :
=D5H :
Example of communication data (when inverter number is 1)
OP
SUM
EM
CR or
1
A
SUM
CR+LF
DT
SUM
EM
CR or
4 0 0 6 SUM
CR+LF
OP
SUM
EM
CR or
1
C
SUM
CR+LF
OP
SUM
EM
CR or
1
D
SUM
CR+LF
OP
SUM
EM
CR or
1
E
SUM
CR+LF
"@"
"O"
50.00Hz→5000D→1388H
40H+01H+4FH+13H+88H=12BH
Checksum
Transmission from inverter to computer
·
External thermal alarm (14)
HD
IN
OP
*
0
1
A
0
·The response is 0 if no alarm is detected.
·Refer to list of alarm codes for details of alarm numbers.
·
F4006=1
HD
IN
OP
*
0
0
B
0
·The read data is a fixed floating-point value, with a same format as the
display on the operation panel of the inverter.
·If a read error occurs, "eXXXX" is returned as an error code. See list
of error codes for details of the error codes.
·Refer to "Note" for the read data format of F5001 (motor poles,
voltage and capacity).
·
Output frequency: 50 Hz
HD
IN
OP
*
0
1
C
0
·
The frequency data is multiplied by 100.
·
Output current: 12[A]
HD
IN
OP
*
0
1
D
0
·
The current data is multiplied by 10.
·
DC voltage: 600V
HD
IN
OP
*
0
1
E
0
·
The voltage data is multiplied by 10.
- 171 -
DT
SUM
0
0
1
4
SUM
DT
SUM
0
0
0
1
SUM
DT
SUM
5
0
0
0
SUM
DT
SUM
0
1
2
0
SUM
DT
SUM
6
0
0
0
SUM
EM
CR or
CR+LF
EM
CR or
CR+LF
EM
CR or
CR+LF
EM
CR or
CR+LF
EM
CR or
CR+LF