Sanken S06-4A005-B Instruction Manual page 53

High performance vector control multifunction inverter
Table of Contents

Advertisement

1704
Overload alarm level
setting value
1705
Motor type
1706
Function
to
switch
between
"OV"
and
"LV"
alarms
when
stopped
1707
Missing Phase
detection function
1708
Overvoltage
stalling
prevention function
1709
Feedback signal
disconnection
detection time
1710
Carrier frequency
variable by lowering
temperature
(Active when only
mode A is selected)
1801
Inverter host software
version query
1802
Memory Version query
1803
Operation panel
software version query
1804
Operation time display
1805
Reading alarm data
1806
Alarm
status
confirmation1
1807
Alarm
status
confirmation2
1808
Alarm
status
confirmation3
1809
Alarm
status
confirmation4
1810
Alarm
status
confirmation5
Special functions
1901
Energy-saving
mode
selection
1902
Simple energy saving
rate
1903
Simple energy saving
time
2001
V•f separation
function selection
2002
V·f separation
command voltage
2003
Arbitrary V/f pattern
intermediate voltage 1
2004
Arbitrary V/f pattern
intermediate voltage 2
2005
Arbitrary V/f pattern
1:Yes, V/F mode, (Currently selected
acceleration/deceleration time)
2:Yes, V/F mode, (1st acceleration/deceleration time)
3:Yes, V/F mode,
(2nd acceleration/deceleration time)
4:Yes, V/F mode,
(3rd acceleration/deceleration time)
5:Yes, V/F mode, (4th acceleration/deceleration time)
6:Yes, V/f mode and speed vector control mode
(1st acceleration/deceleration time)
7:Yes, V/f mode and speed vector control mode
(2nd acceleration/deceleration time)
8:Yes, V/f mode and speed vector control mode
(3rd acceleration/deceleration time)
9:Yes, V/f mode and speed vector control mode
(4th acceleration/deceleration time)
A MODEL
B MODEL
1:General-purpose motor
2:Exclusive motor for the inverter
0:"OV" enabled, "LV" disabled when stopped
1:"OV" disabled, "LV" enabled when stopped
2:"OV" disabled, "LV" disabled when stopped
3:"OV" enabled, "LV" enabled when stopped
0:No input phase loss, no output phase loss
1:Input phase loss, no output phase loss
2:No input phase loss, output phase loss
3:Input phase loss, output phase loss
0:No overvoltage stalling prevention function.
1:Overvoltage stalling prevention function.
0:Only warning
0.01 -119.99 sec.
120: No detection
0:Disabled
1:Enabled
Read only
Read only
Read only
Read only
0:No function
1:Read start
9:Record erase
Read only
Read only
Read only
Read only
Read only
0:No function
1:Simple energy-saving mode (V/f mode)
2:Auto energy-saving mode
0~50%
0~65000s
1:V · f proportional separation
2:Complete separation
0:Disabled (command is given by VIF1)
0.01~40.95V
0~460V
0~460V
0.05~400Hz
20~200%
20~150%
- 52 -
1%
150
120
1
1
1
0
1
3
1
1
0.01 s
5
1
0
Version
Version
Version
1 hour
---
1
0
---
---
---
---
---
---
---
---
---
---
1
0
1%
0
1s
10
1
1
0.01V
0
1V
0
1V
0
0.01Hz
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents