Sanken S06-4A005-B Instruction Manual page 125

High performance vector control multifunction inverter
Table of Contents

Advertisement

Disturb Operation Function(F2201=2)
Disturb operation function (F2201=2)
F2236
Disturb modulation analog input switching
F2237
Disturb modulation rate
● The function to periodically set the frequency change and repeat the actions through the pre-set acceleration/deceleration time.
According to the difference between the shaft diameters of front end and terminal end, it is effective for the system desiring to
change the rotating speed.
● For the frequency set in disturb operation, since it is freely modulated according to external analog command, the setting value of
repeated frequency can be adjusted in conjunction with load status.
Code No.
Function Name
F2236
Disturb modulation analog
input switching
F2237
Disturb modulation rate
1)
Use of inverter terminal
Control terminal
VIF1 ~VIF3
ACM1、ACM2
2)
Basic actions of disturb operation
● Please set F2201=2 (disturb operation). No matter what is the control mode of the motor, the disturb operation is
always effective.
● Since there are two settings of frequency value, it must be set according to 1
frequency (F2102).
● When an operation command is input, the both frequencies will be repeated with a sequence of 1
nd
frequency→2
order to prevent twining, an increase/decrease (△F) will be made to the instantaneously set frequency. When 1
frequency is reached, 8
frequency; when 2
The next set frequency when 1
The next set frequency when 2
● For start (from operation command ON to the 1
of the acceleration and deceleration time during disturb operation, the frequency is changed through 1
acceleration/deceleration time, furthermore, it can also be changed through 2
0: No analog input
1:External analog VRF1voltage(0~5V)
2: External analog VRF1voltage (0~10Vor potentiometer)
3:External analog VRF/IRFvoltage(0~5V)
4 : External analog VRF/IRFvoltage ( 0 ~ 10Vor
potentiometer)
5:Reserved
6:Reserved
7:Reserved
8:External analog VRF/IRFcurrent(4~20mA)
9:Reserved
0~50%
Content
Modulation signal input
Analog signal public terminal
st
speed frequency→1
speed frequency...Also, when output frequency reaches the preset frequency, in
th
speed frequency (F2108) will be used to subtract the preset frequency from 1
nd
speed frequency is reached, this value will be added to act as the set frequency.
st
speed frequency is reached→1
nd
speed frequency is reached→2
Data Content
Function code setting
st
speed frequency – 8
nd
speed frequency + 8
st
speed frequency is reached) and stop (from stop command ON to stop)
- 124 -
Setting Resolution
1
1%
F2236
st
speed frequency (F2101) and 2
th
speed frequency (△F).
th
speed frequency (△F).
nd
acceleration/deceleration time.
Factory Presets
0
0
nd
speed
st
speed
st
speed
st
speed
st

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents