Sanken S06-4A005-B Instruction Manual page 109

High performance vector control multifunction inverter
Table of Contents

Advertisement

Code No.
Function Name
F1802
Memory Version query
● The functional code to read dedicated data.
● Show the storage version of the inverter as
Operation panel software version query
F1803
Show the software version of operation panel.
Code No.
Function Name
F1803
Operation panel software
version query
● The functional code to read dedicated data.
● Show the software version of currently connected operation panel as "
F1804
Operation time display
The inverter displays the accumulated time of operation by the unit of time.
Code No.
Function Name
F1804
Operation time display
● The functional code to read dedicated data.
F1805
Reading alarm data
The function to read the five alarms stored by time sequence.
Code No.
Function Name
F1805
Reading alarm data
● The function to read the alarms displayed on the inverter. Read the last five alarms.
● In case that the alarm will not be recorded, it will display "
● The record will be erased when F1805=9. Meanwhile, the data of F1806 ~ F1810 will also be erased.
● Please refer to "5-5-4 Reading operations of alarm data" for details.
Note 1: This code cannot be written with the communication function; otherwise, the undefined response will be replied.
F1806
Alarm status confirmation1
F1807
Alarm status confirmation2
Alarm status confirmation3
F1808
F1809
Alarm status confirmation4
F1810
Alarm status confirmation5
The function of the inverter to read output frequency, output current and other data when the alarm stops.
Code No.
Function Name
F1806
Alarm status confirmation1
F1807
Alarm status confirmation2
F1808
Alarm status confirmation3
F1809
Alarm status confirmation4
F1810
Alarm status confirmation5
● The functional code to read dedicated data.
● In case that the alarm will not be recorded, it will display "
● When F1805=9 is set, the data recorded in F1806 ~ F1810 will be erased.
● Please refer to "5-5-5 Alarm status confirmation operation" for detailed operation method and display content.
Note 1: This code cannot be written with the communication function; otherwise, the undefined response will be replied.
Note 2: The motor parameters will automatically test the alarm status in 1 and 2, but only the alarm name will be displayed, other
status will be displayed as 0 and will not be recorded.
Data Content
Memory Version
XXXX. XXXX represents the storage version.
Data Content
Operation panel software version
XXXX". XXXX represents the software version.
Data Content
Operation time
Data Content
0: No function
1: Read start
9: Record erase
" when F1805=1 is set.
Data Content
Inverter status in case of an alarm
(alarm name, output frequency, output current,
output voltage, DC current, output power, radiator
fin temperature)
" when F1805=1 is set.
- 108 -
Setting Resolution
Factory Presets
Setting Resolution
Factory Presets
Setting Resolution
Factory Presets
1 hour
Setting Resolution
Factory Presets
1
0
Setting Resolution
Factory Presets