Sanken S06-4A005-B Instruction Manual page 158

High performance vector control multifunction inverter
Table of Contents

Advertisement

Gain torque command(VIF1)
nd
inverter)
(2
Gain torque command(VIF1)
st
(1
inverter)
Bias torque command(VIF1)
st
nd
and 2
(1
● The torque command at forward and reverse rotation sides can be set synchronously.
Example) When torque command is set with analog signal VIF2 (4-20mA) and a range of ±100%,
Select torque command: F6101=9.
Setting of bias and gain: F6109=100%, F6110=100%.
Gain torque command(VIF2)
Bias torque command(VIF2)
Note: Actual torque command value is the limiting value set by F6103-F6106.
Reference parameter
F6101(
Torque command selection
Torque characteristics selection in constant power zone
F6113
The function to torque limit in constant power zone.
Code No.
Function Name
F6113
Torque characteristics selection in
constant power zone
● During constant torque constant power limit, when motor output (set by F5001) is fixed in constant power zone (exceed the speed
range of rated speed), the torque command value will decrease automatically. (Factory presets)
Rated speed (set by F5004) × motor torque = motor power: (fixed in constant power zone).
● During constant torque limit, the torque command will not decrease, and will operate with a fixed torque command.
● During constant torque (speed range within rated speed), if it is not set according to this function, it will run with a fixed torque
command.
● According to the settings of this function, the relationship between speed range and torque is shown as follows.
Torque command of 2
)。
0: Constant torque constant power limit
1: Constant torque limit
nd
inverter
Torque command of 1
Torque command
Data Content
- 157 -
st
inverter
Factory
Setting Resolution
Presets
1
0