Sanken S06-4A005-B Instruction Manual page 57

High performance vector control multifunction inverter
Table of Contents

Advertisement

value
3107
PID2 feedback signal
input filter time
constant
3108
Indirect
PID2
input
reference
3109
PID2 deviation limit
value
3110
PID2 utput limit value
3111
PID2 operation
polarity switching
3112
PID2 gain polarity
switching
3113
PID2 command value
gain
3114
PID2 feedback value
gain
3115
PID2 control
proportional gain
(negative:F3012=2)
3116
PID2 control integral
time
(negative:F3012=2)
3117
PID2 control command
value
3118
PID2 control feedback
value (communication
function)
3119
Frequency
corresponding to PID2
control maximum
command value
3123
PID start mode
selection
3124
PID end mode
selection
3125
PID end setting value
3127
For factory adjustment
3201
PID control action
selection
3202
For factory adjustment
3203
External PID control
selection
3204
External PID operation
mode selection
3205
PID constitution
selection
3206
Command value
addition
calculation PID control
gain
3207
PID1/PID2
switching
time
3301
Reading PID1
command value
3302
Reading PID1
feedback value
3303
Reading PID1 input
deviation
3304
Reading PID1 output
value
3305
Reading PID2
command value
1~500(set value 1=10ms)
5~100%(target value reference)
0:No limit
1~100%(upper frequency limit reference)
0:No limit
1~100%(upper frequency limit reference)
1:Command value – feedback value
2:Feedback value – command value
1:The plus or minus deviation indicates the same gain
2:The plus or minus deviation indicates different gains
0~50
0~50
0~100
0.01~100s
0~4000
0~4000
0~400Hz
1:Direct input mode
2:Condition input mode
1:Direct end mode
2:Condition end mode
1~100%(upper frequency limit standard)
0:Open loop control
1:PID1 control
2:PID2 control
3:For factory adjustment
4:External terminal switching PID control
5:Timing switch PID control
0:No external PID control
1:External control PID1
2:External control PID2
3:For factory adjustment
4:external controls PID1 and PID2
5:For factory adjustment
6:For factory adjustment
1:Operation interlocked with inverter operation
2:PID output after power input
3:PID output controlled by external terminals
0:Without command value addition calculation
1:With command value addition calculation
0.01~100
0.1~6000 minutes
Read only
Read only
Read only
Read only
Read only
- 56 -
1
10
0.1%
20
0.1%
100
0.1%
100
1
1
1
1
0.01
1
0.01
1
0.01
0.1
0.01s
0.1
0.1
0
0.1
0
0.01Hz
60
1
1
1
1
0.1%
20
1
0
1
0
1
1
1
0
0.01
1
0.1 minute
0.1
1
---
1
---
1
---
1
---
1
---