operation is stopped will be used when trying to move to the next cycle.
Code No.
Function Name
F2218
Operation stop time T0
Note 1: The frequency cannot be specified during the operation stop time T0. Usually under the status of stopping
deceleration.
Note 2: The deceleration time in stopping action will decelerate from first deceleration time to fourth deceleration time
specified by midway stop deceleration time (F2219).
Note 3: When the operation stop time T0 is finished and the inverter is still stopping deceleration, it will last until the
inverter is fully stopped, otherwise, it will not enter the next cycle. Therefore, the stop time of T0 should be set
longer than the time from T15 to deceleration stopping.
Note 4: The braking mode is the same as usual operation. (DC braking, braking excitation, idle stopping are effective)
Note 5: When operation stop time is not required, please set F2218=0. When move the cycle from T15 to T1, the inverter
will operate continuously.
Frequency
6) Use of frequency value for each timer
The frequency of each timer is set by function codes of multi-speed frequency (1
functions. However, for the frequency set for T1, when 1
frequency (F2101) is the set frequency; for occasions other than 1, 21 and 22, the set frequency is the frequency set for
specified function.
Setting method
Operation timer
Operation timer T1
Operation timer T2~T15
Note 1: During actions of each operation timer (T1~T15), if the frequency is changed by multi-speed frequency code
(F2102~F2115), direct step setting or terminal stepping functions, the frequency in current operation
timer will also change. Furthermore, the changed frequency will be shown in the function codes of
multi-speed frequency. Example)
the operation panel, make an acceleration/deceleration according to the changed frequency, enter the changed
frequency values in to F1202.
Note 2: Since the simple graph operation will specify multi-speed frequency in each timer, the multi-speed changes
made for control circuit input terminals will be noneffective.
0~65000s
Midway stop deceleration time
Selected by F2219
Deceleration Stop
Inverter stop
First cycle
F1002=2~20
F1002=26~28
Absolute value of analog input frequency(VRF1、VRF/IRF terminals)
Data Content
Second cycle
st
speed frequency (F1002) selects 1, 21 and 22, the 1
Content
st
F1002=1、21、22
1
speed frequency (F2101)
Analog frequency input(VRF1、VRF/IRF terminals)
F1002=25
Pulse train input
(Rotation direction as specified by F2221)
Decided by contents of F2102~F2115=0~400Hz
When operation timer T2 is running and the frequency is changed on
- 120 -
Setting Resolution
Factory Presets
1s
10
Time
st
th
~ 15
speed frequency) with standard
st
speed