Main Index > Configuration > Configuration 2
Parameter
Function
Dehum tmp prio
Dehumidification Control (tmpPrio= if
Heating > 90% DeHum is decreased)
Dew point control
Dew Point Control (only possible with Hum
Supply and Tmp Sply Sensor)
Hum deviation alarm
Alarm if the Humidification Setpoint is not
reached
Room or Exhaust Air is monitored
Supply Air is monitored
Supply and Room or Exhaust Air are
monitored
(only possible with a Room or/and a Supply
Sensor)
Humidifier pump
Humidification Pump
Humidification Pump with Pump kick function
Hum pump alarm
Alarming for Humidification Pump
Humidifier fdbk
Generally Humidification Feedback
Cooling pump
Cooling Pump
Cooling pump alarm
Alarming for Cooling Pump
Coolng DX alarm
Alarming for Dx Cooling
Htg 2 frost protect
Heating 2 Frost function
Only Sensor
Sensor with 2 Setpoints
Only Detector
Sensor and Detector
Sensor with 2 Setpoints and Detector
Heating 2 pump
Heating 2 Pump
Heating pump with Pump kick function
Heating 2 pump alm
Alarming for Heating 2 Pump
Heating 2 control
Heating 2 Control
(In Sequence = additionally Heater eg.
ReHeater)
El heating 2 alarm
Electrical heating 2 alarm
El Heating 2 control
Electrical heating 2 Control
(In Sequence = additionally Heater eg.
ReHeater)
Cooling 2 pump
Cooling 2 Pump
Cooling 2 pump alm
Alarming for Cooling 2 Pump
Cooling 2 Dx alarm
Alarming for Dx Cooling 2
Cooling 2 control
Cooling 2 Control
(In Sequence = additionally Cooler
Fire damper fdbk
Fire damper Feedback signals
Only one fdbk for Closed
Two fdbk's opened and closed
One fdbk signalise opened and closed (
1=>0=>1 = closed => move => opened)
Auxiliary input
Auxiliary input Function
Input = Auxiliary input only for Display
alarm = Input for alarm
Inp+Alm = 2 Auxiliarx Inputs one for Display
one for alarm
Siemens
Building Technologies
Basis Document Siemens Climatix Control System
Standard application AHU
BDCX.100820.01GB
HMI
Value range
Unit
No/Yes
No/Yes
No
RoomExhaust
Supply
Sply+RmRtr
No
Yes
Yes+Kick
No
alarm
fdbk
both
No
Yes
No
Yes
Yes+Kick
No
alarm
fdbk
both
No
alarm
fdbk
both
No
sensor
Sensor2Spv
Detector
Snsr+Dtctr
2Spv+Dtctr
No
Yes
Yes+Kick
No
alarm
fdbk
both
StandAlone/
InSequence
No/Yes
StandAlone/
InSequence
No
Yes
Yes+Kick
No
alarm
fdbk
both
No
alarm
fdbk
both
StandAlone/
InSequence
Clsd
Clsd+Opnd
Combined
No
Input
alarm
Inp+Alm
Standard
R
S Link
No
4
No
4
No
4
No
No
4
No
4
Yes+Kick
4
alarm
4
alarm
4
No
4
Yes+Kick
4
alarm
4
Section:
15.2
StandAlone
4
No
4
StandAlone
4
Yes+Kick
4
alarm
4
No
4
StandAlone
4
Clsd
4
No
4
183 / 244