Main Index > Configuration
Parameter
Function
Configuration by
Choose the way of configuration
Indicator if Configuration 1 is finished.

Configuration 1

Jumpline to Configuration 1
Indicator if Configuration 2 is finished.
Configuration 2
Jumpline to Configuration 2
Indicator if Configuration IO's is finished.
Configuration IO's
Jumpline to the IO Configuration
Check Config IO's
Jumpline to the IO check
If you have configured one In or Output more
Doubled
than once, you get a Fault
If you have configured a function, and not
Not Configured
configured the needed IO's you get a Fault.
Jumpline to the configuration of the
Integrations
communication
RoomUnit1
Jumpline to room Unit 1 (not implemented)
RoomUnit2
Jumpline to room Unit 2 (not implemented)
Main Index > Configuration > Configuration 1 --- General
Parameter
Function
Extension modules
Number of extension modules
Fire alarm
Kind of Fire alarm
alarm = digital Input for alarm
tmp = Supply /Exhaust Temperatur are
supervised
alarm+tmp = both variants are active
Filter alarm
Existing Filter alarms
Combined = one alarminput for both Filters
Supply = only Supply Filter
Exhaust = only Exhaust Filter
Sply+Exh = both Filter with separate Inputs
Emergency stop
Digital Input Emergency stop
alarm ackn input
Digital Input for Alarm ackn button Button
Su/Wi input
Digital Input for Summer Winter Change over
TRUE = Summer
TSP function
Select the needed Scheduler function
No = Scheduler disabled
Step = possible OpMode Off / [Number of
Steps selected in TSP Steps]
Step+tmp = possible OpMode Off/ [Number
os Modes selected in TSP Steps]
TSP Steps
If TSP function = Step: Number of Steps for
Fan
If Tsp Functon = Step+Temp: Number of
Setpoints (Off /Eco1-3 /Com1-3)
178 / 244
Basis Document Siemens Climatix Control System
Siemens
Page 178
BDCX.100820.01GB
Building Technologies
17.4

Main overview

Diese Seite enthält eine Übersicht aller Hauptwerte der konfigurierten Applikation.
17.5
Configuration
Write access 4 required to go to this page.
17.6

Configuration 1

Write access 4 required to go to this page.
Standard application AHU
HMI
Value range
Unit
HMI Config
Download
NotDone
Done
NotDone
Done
NotDone
Done
OK.
Fault
OK.
Fault
Value range
Unit
No
One
Two
No
alarm
tmp
alarm+tmp
No
Combined
Supply
Exhaust
Supply+Exhaust
No
Yes
No
Yes
No
Yes
No
Step
Step+tmp
1Step
2Steps
3Steps
Standard R
S Link
Download
4
4
4
Section:
4
15
Standard R
S Link
No
4
No
4
No
4
Yes
4
No
4
No
4
Section:
0
Step
4
1St
4
CE1P3977en_02
01.02.2010