Siemens Climatix Series Basis Document page 173

Hide thumbs Also See for Climatix Series:
Table of Contents

Advertisement

HW IO
El heating DO2
Heating AO
Heating pump DO
Hrec damper AO
Heat recovery AO
Hrec pump DO
Cooling AO
Cooling pump DO
Cooling DX DO1
Cooling DX DO2
El heating 2 AO
El heating 2 DO1
El heating 2 DO2
Heating 2 AO
Heating 2 pump DO
Cooling AO
Cooling 2 pump DO
Cooling 2 DX DO1
Cooling 2 DX DO2
Terminal positions for
digital outputs
Klemmenpositionen
analoge Ausgänge
(0...10 V DC)
Siemens
Building Technologies
Pos
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,DO1..DO24
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,X3..X28,AO1...AO22
NUsd,Comm,DO1..DO24
NUsd,Comm,DO1..DO24
NUsd,Comm,DO1..DO24
Position
Explanation
DO1...DO6
Terminal on basis controller.
DO11...DO14
Terminal on extension module 1.
DO21...DO24
Terminal on extension module 2.
Comm
This output is connected via communication and therefore does
not occupy a hardware input. Some output signals can also be
connected via communication (see lists in the documentation on
the basics for LON, ModBus, BacNet).
Outputs may generally be enabled in parallel as well (via hardware
and communication).
NUsd
No used: The hardware position is not yet selected. The plant is
locked against switching on if an enabled sensor is set to NUsd
and the following fault issued: NotConfigured (Function enabled,
but hardware not assigned).
Position
Explanation
X3...X8
Terminal on basis controller.
AO1,AO2
Terminal on basis controller.
X11...X18
Terminal on extension module 1.
AO11,AO12
Terminal on extension module 1.
X21...X28
Terminal on extension module 2.
AO21,AO22
Terminal on extension module 2.
Comm
This output is connected via communication and therefore does not
occupy a hardware input. Some output signals can also be con-
nected via communication (see lists in the documentation on the
basics for LON, ModBus, BacNet).
Outputs may generally be enabled in parallel as well (via hardware
and communication).
NUsd
No used: The hardware position is not yet selected. The plant is
locked against switching on if an enabled sensor is set to NUsd
and the following fault issued: NotConfigured (Function enabled,
but hardware not assigned).
Basis Document Siemens Climatix Control System
Standard application AHU
BDCX.100820.01GB
Configuration
173 / 244
CE1P3977en_02
Page 173
01.02.2010