Siemens Climatix Series Short Manual
Hide thumbs Also See for Climatix Series:

Advertisement

Control equipment
Climatix
Short Manual
Climatix Control System
[v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40]

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Climatix Series

  • Page 1 Control equipment Climatix Short Manual Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40]...
  • Page 3: Table Of Contents

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 1 Table of contents External HMI (DM) .................. 3 Functions ....................7 Overall functions ..................7 Operating mode ..................9 Time switch program - details ..............13 Week scheduler ..................
  • Page 4 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 2...
  • Page 5: External Hmi (Dm)

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 3 External HMI (DM) Operating elements The external HMI has the following operating elements: Hand unit INFO Navigation and Explanation/help. OK dial. No light = Stop Turn clockwise or counterclockwise Steady green light =...
  • Page 6 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 4 Display screen Displays menus, parameters, parameter settings, operating settings, etc. Navigation and OK dial ● ● Select menus, parameters, parameter values: Turn. ● ● Other parameter values: Turn. ●...
  • Page 7 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 5 Display screen Display design: Present access levels: - No symbol: No level - 1:a key: basic access level (Password enter: 1000) - 2:a key: normal access level (Password enter: 2000) - 3:e key: technical access level Title of displayed pages.
  • Page 8 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 6 When only one value is selectable: To set discrete parameter values.. Stage 1 Stage 1 Stage 1 The checked off line (Fire Setpoint) displays the presently set value. Change the value as follows: ●...
  • Page 9: Functions

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 7 Functions Overall functions 2.1.1 General This section describes special functions that relate to the application as a whole. Parameter Main menu > Overall functions. Parameter Value Function –...
  • Page 10 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 8 Main menu > General func. > Summer-winter calculation Parameter Value Function Status Status for summer/winter changeover: – Winter – Winter operation is enabled. – Summer –...
  • Page 11: Operating Mode

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 9 Operating mode 2.2.1 General Purpose Function to set and display all setings for the operating mode in question, i.e. start conditions, switch-off conditions, operating mode. The plant may also be controlled using the HMI.
  • Page 12 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 10 From BMS Manual plant operation via HMI (only possible for Tsp function = Stages+Tmp). Value can be set via HMI even if communication is deactivated. –...
  • Page 13 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 11 2.2.2 Supply air/extract air fan control Function Fans can be directly controlled, pressure-controlled, flow controlled or controlled as master-slave. Common or separate outputs are used depending on the configuration.
  • Page 14 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 12 Switch on delay. 0…36000 [s] For supply air fan only! Defines switch-on delay for the supply air fan after an extract fan start. Start up delay 0…36000 [s] Defines the period after the fans have started without fdbk.
  • Page 15: Time Switch Program - Details

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 13 Time switch program - details This section describes the functions and entries for time switch programs and calendars. Possible entries vary depending on the configuration. It is set in Configuration 1: Main menu >...
  • Page 16: Day Scheduler

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 14 Day scheduler Parameter Parameter Value Function Present value Switching according to schedule when the present day of the week is the same as the switching day. Day schedule Status of the current week or exception day: –...
  • Page 17 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 15 Examples: Choice-1 = Range The entries in (start) date and end date are relevant. ● ● -(Start) Date = *,23.06.09 / -End date = *,12.07.09 23 June 2009 through 12 July 2009 are exception days (e.g.
  • Page 18: Temperature Control

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 16 Temperature control 2.7.1 General Prerequisites Displays only functions that are enabled in Configuration 1 or Configuration 2. All other functions are hidden. Main menu > Unit > Temp. control Parameterization Parameter Function...
  • Page 19 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 17 2.7.2 Temperature setpoints Prerequisites Displays only functions that are enabled in Configuration 1 or Configuration 2. All other functions are hidden. Parameterization Main menu > Unit > Temp. control > Temp. setpoints Parameter Value Function...
  • Page 20 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 18 Fan clg dead zone 0…20 [°C] Controller dead zone: Setpoint = heating setpoint for supply air – dead zone. If sequence is placed last: Supply air cooling setpoint + dead zone.
  • Page 21: Eco Control

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 19 ECO control Parameter Main menu > Unit > ECO Control Parameter Value Function Sply fan st2 stpt 500l/s Supply fan normal speed winter Maximum speed on supply fan summer (increased Sply fan st3 stpt 800l/s fan speed at cooling and heating demand)
  • Page 22: Alarms

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 20 Alarms General This section deals with the following topics: ● ● Alarms. ● ● Alarm lists. ● ● History lists. ● ● Acknowledged alarms. ● ● Reset alarms. ●...
  • Page 23 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 21 Alarm LED flashing or lit continuously Alarm button functions Press the Press the alarm button alarm button Detailed info Latest alarm Press the alarm button Alarm list Press the alarm button...
  • Page 24: Alarm List Details

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 22 Alarm list details The alarm list contains the following information about the most recent alarm: Line 1 + Alarm name Status Line 2 Notification class (Notification group) Line 3 Date...
  • Page 25: Alarm Settings And History List

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 23 Alarm settings and history list Parameter Parameter Value Function Larm list: Reset Reset / acknowledge pending alarms. Sorting order 1 Main sorting criteria: – Time –...
  • Page 26: Commissioning Modbus

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 24 Commissioning Modbus Commissioning internal Modbus RTU Present units The illustration shows the devices and connections involved in commissioning: POL895.50 POL638.00 24...230V~ 24...230V~ RS 485 Ethernet HMI-DM RS485 Modbus RTU...
  • Page 27 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 25 Select Termination: The RS485 topology must always be terminated using wave resisters. They can be enabled or disabled here. Select Restart: After you are done entering settings; restart the controller using this command.
  • Page 28: Commissioning Internal Modbus Tcp

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 26 Commissioning internal Modbus TCP Present units The illustration shows the devices and connections involved in commissioning: POL895.50 POL638.00 24...230V~ 24...230V~ RS 485 Ethernet HMI-DM Ethernet ModBus TCP Connection Connect Climatix controller to Ethernet (Modbus TCP) using an ordinary network cable.
  • Page 29: Save And Reset Commissioning/Factory Settings

    Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 27 Save and restore commissioning/factory settings After you have entered your settings and adjustments you should save the parameters and settings in both the internal memory of the Climatix controller and in the SD memory in order to be able to restore them after a possible loss of data.
  • Page 30 Short Manual for Climatix Control System [v. 2.14.10, 2.14.20, 2.14.30 & 2.14.40] SMCX.130215.02GB Page 28...