6-11Replacing The Fuses - Horizon Fitness Bookletmaker SPF-200A Manual

Table of Contents

Advertisement

6-11
Replacing the Fuses
- Fuse replacement must be supervised by a maintenance administrator.
- Turn off the power switch and unplug the power cord before replacing a fuse.
1
Identify which fuse has blown by
checking the machine.
1102
Error Code
- Any fuse may be blown if the following error
codes are displayed on the Error screen.
Error Code
1102
Fuse F02 on the SPF Power Board
QPW-757
4102
Fuse F1 on the Fore-edge Trim Knife
8300
Section Control Board QPM-237
- If an error code is not displayed, some
symptoms can indicate the problem. Iden-
tify which fuse has blown by checking the
symptom.
Symptom
- The delivery
Fuse F60 on the SPF Power
conveyor does
Board QPW-757 (if the delivery
not move.
conveyor is installed on the SPF
main unit).
Fuse F60 on the Fore-edge Trim
Knife Section Power Board
QPW-757 (if the delivery con-
veyor is installed on the fore-
edge trim knife section.)
- The trim is not
Fuse F02 on the Fore-edge Trim
collected. (The
Knife Section Power Board
blower does not
QPW-757
work.)
WARNING
11119
61101A1
Fuses
Rear Side of Machine
11119
61101E1
Fuses
Spare Fuses
Fore-edge Trim Knife Section
Control Board QPM-237
F1
F1
F1
(3.15A)
(3.15A)
(3.15A)
11119
61101C1
Power Board QPW-757
11119
61101F1
11119
61101B1
Power Board
6
QPW-757
F02
(1.0A)
F60
(0.5A)
11119
61101G1
Spare Fuses
137