5-1
If an Icon Is Displayed on the Error Screen
800 to 899
SPF Option Error
Front Stitch Detection
821
Error
Rear Stitch Detection
822
Error
Front Stitch Mis-Detec-
831
tion
Rear Stitch Mis-Detec-
832
tion
Front Wire Feeding
836
Error
837
Rear Wire Feeding Error
Fore-edge Trim Section
900 to 999
Option Error
TD-200 Booklet Thick-
900
ness Error
1100 to 1199
SPF Section System Error
1100
Interlock Contactor Fault
1101
Inverter Alarm
Body Pulse Detection
1102
Error
Electrical Box Cooling
1103
Fan 1 Alarm
Electrical Box Cooling
1104
Fan 2 Alarm
1120
Stitching Motor Alarm
1140
Folding On/Off Error
Fold Knife Operation
1141
Error
Transport Pulse (Infeed
1151
Section) Detect Error
Transport Pulse (Deliv-
1152
ery Section) Detect Error
Stitching Motor Opera-
1170
tion Error
Downstream Device
1198
Power Down while
Operation
Downstream Device Not
1199
Connected/Interlock Dis-
connection Error
The machine did not make a front stitch.
Check if the wire has run out, or if the wire is jammed.
The machine did not make a rear stitch.
Check if the wire has run out, or if the wire is jammed.
A front stitch has detected incorrectly.
(A stitch has detected at a time independent of the sheet transportation.)
Check if the wire is mounted on the sensor, or the guide bar is too close to the sensor.
A rear stitch has detected incorrectly.
(A stitch has detected at a time independent of the sheet transportation.)
Check if the wire is mounted on the sensor, or the guide bar is too close to the sensor.
There is a problem with the wire feed.
Check if the wire has run out, or if the wire has jammed inside the stitcher head. If the
problem occurs again although the wire is OK, change the wire feeding detection set-
ting. (Refer to Section 3-5, step 4.)
Using the Administrator Mode screen, set the number of times the machine can miss
a stitch before this error is detected. (Refer to page 31.)
There is a problem with the wire feed.
Check if the wire has run out, or if the wire has jammed inside the stitcher head. If the
problem occurs again although the wire is OK, change the wire feeding detection set-
ting. (Refer to Section 3-5, step 4.)
Using the Administrator Mode screen, set the number of the machine can miss a
stitch before until this error is detected. (Refer to page 31.)
A thickness error has been detected and the operation stopped immediately. Check
the booklet thickness.
There is a problem with the interlock contactor K00. Please call your local dealer.
Turn off the power switch, wait about 10 minutes, then turn it on again.
If the problem occurs again, please call your local dealer.
Check if the body of the machine moves forward or backward when you press the
body forward/backward movement motor M02 on the Information-Single Operation
screen. If the body does not move, fuse F02 may be blown. Replace the fuse. (Refer
to Section 6-11.) If the fuse is OK, please call your local dealer.
The binding operation can be continued temporarily by changing the installation posi-
tion of the machine.
Cooling fan M03 is not turning. Please call your local dealer.
Cooling fan M04 is not turning. Please call your local dealer.
The stitching motor driver A20 (SPF) has produced an error.
Turn off the power switch, wait about 10 minutes, then turn it on again.
If the problem occurs again, check if circuit breaker Q20 is tripped. If Q20 is tripped,
turn it on again. If the breaker is OK, please call your local dealer.
Sheets have been transported to the fold section although the job does not require
folding, or sheets have been transported to the horizontal transport section although
the job requires folding. Please call your local dealer.
Although the fold knife should move, the fold knife home position sensor keeps turn-
ing on so the fold knife does not move.
Check if circuit breaker Q01 is tripped. If Q01 is tripped, turn it on again. If the breaker
is OK, please call your local dealer.
Check if circuit breaker Q01 is tripped. If Q01 is tripped, turn it on again. If the breaker
is OK, please call your local dealer.
The machine did not verify that the stitching operation was done and the stitcher was
raised to the upper limit.
The stitching motor ran but the stitching operation did not finish correctly. Please call
your local dealer.
The power for a downstream device was turned off while the machine was trying to operate.
Check the connector on the left side of the SPF-200A/200L. (Refer to Section 1-2-2.)
If the connector is connected correctly, please call your local dealer.
Check the downstream device is connected to the SPF-200A/200L correctly, or the
downstream device is powered on.
If the delivery conveyor is used as a downstream device, check if the short circuit
connector for stand-alone use is connected. (Refer to Section 1-2-2.)
If the problem occurs again, please call your local dealer.
Cause and Solution
Cause and Solution
Cause and Solution