Parameter Descriptions
5-60 Terminal 27 Pulse Output Variable
Option:
[103]
Motor Current
[104]
Torque rel to
limit
[105]
Torq relate to
rated
[106]
Power
4
4
[107]
Speed
[108]
Torque
[109]
Max Out Freq
[113]
Ext. Closed
Loop 1
5-62 Pulse Output Max Freq #27
Range:
Size
related
Hz]
*
5-63 Terminal 29 Pulse Output Variable
Option:
[0]
No operation
[45]
Bus ctrl.
[48]
Bus ctrl.,
timeout
[100]
Output
frequency
[101]
Reference
[102]
Feedback
[103]
Motor Current
[104]
Torque rel to
limit
[105]
Torq relate to
rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max Out Freq
[113]
Ext. Closed
Loop 1
5-65 Pulse Output Max Freq #29
Range:
Size
related
Hz]
*
78
Function:
Function:
[0 - 32000
Set the maximum frequency for
terminal 27 corresponding to the
output variable selected in
parameter 5-60 Terminal 27 Pulse
Output Variable.
Function:
Select the display output for
terminal 29.
Function:
[0 - 32000
Set the maximum frequency for
terminal 29 corresponding to the
output variable set in
parameter 5-63 Terminal 29 Pulse
Output Variable.
Danfoss A/S © 03/2019 All rights reserved.
VLT® AutomationDrive FC 361
5-66 Terminal X30/6 Pulse Output Variable
Select the variable for readout on terminal X30/6.
This parameter is active when VLT
is installed in the frequency converter.
Same options and functions as parameter group 5-6* Pulse
Outputs.
Option:
[0]
*
[45]
[48]
[100]
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
[109]
[113]
5-68 Pulse Output Max Freq #X30/6
Range:
5000 Hz
®
General Purpose I/O MCB 101
Function:
No operation
Bus ctrl.
Bus ctrl.,
timeout
Output
frequency
Reference
Feedback
Motor Current
Torque rel to
limit
Torq relate to
rated
Power
Speed
Torque
Max Out Freq
Ext. Closed
Loop 1
Function:
NOTICE
[0 - 32000
*
Hz]
This parameter cannot be
adjusted while the motor is
running.
Select the maximum frequency on
terminal X30/6 referring to the
output variable in
parameter 5-66 Terminal X30/6 Pulse
Output Variable.
This parameter is active when VLT
General Purpose I/O MCB 101 is
installed in the frequency converter.
®
MG06J202