Parameter Descriptions
4.15.5 16-6* Inputs and Outputs
16-60 Digital Input
Range:
Function:
0
[ 0 - 1023 ]
View the signal states from the
*
active digital inputs. Example: Input
18 corresponds to bit number 5, 0
= no signal, 1 = connected signal.
Bit 6 works in the opposite way, on
= 0, off = 1 (Safe Torque Off input).
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10–
63
Table 4.20 Active Digital Inputs
0 0
Illustration 4.47 Relay Settings
MG06J202
Programming Guide
Digital input terminal
33.
Digital input terminal
32.
Digital input terminal
29.
Digital input terminal
27.
Digital input terminal
19.
Digital input terminal
18.
Digital input terminal
37.
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/4.
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/3.
®
Digital input VLT
General Purpose I/O
MCB 101 terminal X30/2.
Reserved for future
terminals.
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0
D I T - 3 3
D I T - 3 2
D I T - 2 9
D I T - 2 7
D I T - 1 9
D I T - 1 8
D I T - 3 7
D I X 3 0/4
D I X 3 0/3
D I X 3 0/2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Danfoss A/S © 03/2019 All rights reserved.
16-61 Terminal 53 Switch Setting
Option:
Function:
View the setting of input terminal
53.
[0]
Current
*
[1]
Voltage
16-62 Analog Input 53
Range:
Function:
0
[-20 - 20]
View the actual value at input 53.
*
16-63 Terminal 54 Switch Setting
View the setting of input terminal 54.
Option:
Function:
[0]
Current
*
[1]
Voltage
16-64 Analog Input 54
Range:
Function:
0
[-20 - 20]
View the actual value at input 54.
*
16-65 Analog Output 42 [mA]
Range:
Function:
0
[0 - 30]
View the actual value at output 42
*
in mA. The value shown reflects the
selection in parameter 6-50 Terminal
42 Output.
16-66 Digital Output [bin]
Range:
Function:
0
[0 - 15]
View the binary value of all digital
*
outputs.
16-67 Pulse Input #29 [Hz]
Range:
Function:
0
[0 - 130000 ]
View the actual frequency rate on
*
terminal 29.
16-68 Freq. Input #33 [Hz]
Range:
Function:
0
[0 - 130000]
View the actual value of the
*
frequency applied at terminal 33 as
an impulse input.
16-69 Pulse Output #27 [Hz]
Range:
Function:
0
[0 - 40000]
View the actual value of pulses
*
applied to terminal 27 in digital
output mode.