Parameter Lists
15-92 Defined Parameters
15-93 Modified Parameters
5.2.15 16-** Data Readouts
Param
Parameter description
eter
numb
er
16-0* General Status
16-00 Control Word
5
5
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor current
16-15 Frequency [%]
16-16 Torque [Nm]
16-17 Speed [RPM]
16-18 Motor Thermal
16-20 Motor Angle
16-21 Torque [%] High Res.
16-22 Torque [%]
16-24 Calibrated Stator Resistance
16-3* Drive Status
16-30 DC Link Voltage
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-45 Motor Phase U Current
16-46 Motor Phase V Current
16-47 Motor Phase W Current
16-48 Speed Ref. After Ramp [RPM]
16-49 Current Fault Source
16-5* Ref. & Feedb.
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback[Unit]
16-53 Digi Pot Reference
16-57 Feedback [RPM]
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
174
VLT® AutomationDrive FC 361
0 N/A
0 N/A
Default value
0 N/A
0 ReferenceFeedbackUnit
0 %
0 N/A
0 %
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 Nm
0 RPM
0 %
0 N/A
0 %
0 %
0.0000 Ohm
0 V
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
0 A
0 A
0 A
0 RPM
0 N/A
0 N/A
0 N/A
0 ReferenceFeedbackUnit
0 N/A
0 RPM
0 N/A
[0] Current
0 N/A
Danfoss A/S © 03/2019 All rights reserved.
All set-ups
FALSE
0
All set-ups
FALSE
0
4 set-up
Change
Conversion
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Uint16
Uint16
Type
index
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int16
67
Int32
0
Uint8
0
Uint16
-1
Int16
0
Int16
-4
Uint32
0
Uint16
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
–
Uint8
-2
Int32
-2
Int32
-2
Int32
67
Int32
0
Uint8
-1
Int16
-1
Int16
-3
Int32
-2
Int16
67
Int32
0
Uint16
–
Uint8
-3
Int32
MG06J202