Parameter Lists - Danfoss VLT AutomationDrive FC 361 Programming Manual

90–315 kw, enclosure sizes j8–j9
Hide thumbs Also See for VLT AutomationDrive FC 361:
Table of Contents

Advertisement

Parameter Lists

5.2 Parameter Lists
5.2.1 0-** Operation / Display
Para
Parameter description
meter
numb
er
0-0* Basic Settings
0-01
Language
0-02
Motor Speed Unit
5
5
0-04
Operating State at Power-up (Hand)
0-1* Set-up Operations
0-10
Active Set-up
0-11
Edit Set-up
0-12
This Set-up Linked to
0-13
Readout: Linked Set-ups
0-14
Readout: Edit Set-ups / Channel
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-25
My Personal Menu
0-3* LCP Custom Readout
0-30
Unit for User-defined Readout
0-31
Min Value of User-defined Readout
0-32
Max Value of User-defined Readout
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-41
[Off] Key on LCP
0-42
[Auto on] Key on LCP
0-43
[Reset] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password
0-61
Access to Main Menu w/o Password
5.2.2 1-** Load and Motor
Param
Parameter description
eter
numb
er
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-03
Torque Characteristics
160
VLT® AutomationDrive FC 361
Default value
0 N/A
[1] Hz
[1] Forced stop, ref=old
[1] Set-up 1
[1] Set-up 1
[0] Not linked
0 N/A
0 N/A
1617
1614
1610
1613
1502
ExpressionLimit
[1] %
0 CustomReadoutUnit
100 CustomReadoutUnit
0 N/A
0 N/A
0 N/A
[1] Enabled
[1] Enabled
[1] Enabled
[1] Enabled
[0] No copy
[0] No copy
100 N/A
[0] Full access
Default value
ExpressionLimit
[1] VVC+
[0] Constant torque
Danfoss A/S © 03/2019 All rights reserved.
4 set-up
Change
Conversion
during
index
operation
1 set-up
TRUE
4 set-ups
FALSE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
4 set-up
Change
during
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
0
Uint16
0
Int32
Uint16
Uint16
Uint16
Uint16
Uint16
0
Uint16
Uint8
-2
Int32
-2
Int32
0
VisStr[25]
0
VisStr[25]
0
VisStr[25]
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
0
Int16
Uint8
Conversion
Type
index
Uint8
Uint8
Uint8
MG06J202