Parameter Descriptions
15-22 Historic Log: Time
Array [50]
Range:
0 ms
*
2147483647
ms]
4
4
4.14.4 15-3* Alarm Log
Parameters in this group are array parameters where up to
10 fault logs can be viewed. 0 is the most recent logged
data, and 9 is the oldest. Fault codes, values, and time
stamp can be viewed for all logged data.
15-30 Fault Log: Error Code
Range:
0
*
15-31 Alarm Log: Value
Array [10]
Range:
0
*
32767 ]
15-32 Alarm Log: Time
Array [10]
Range:
0 s
*
2147483647 s]
4.14.5 15-4* Drive Identification
Parameters containing read-only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Range:
0
*
142
Function:
[0 -
View the time at which the logged
event occurred. Time is measured in
ms since frequency converter start.
The maximum value corresponds to
approximately 24 days, which
means that the count restarts at 0
after this time period.
Function:
[0 - 65535]
View the fault code and look up its
meaning in chapter 6 Trouble-
shooting.
Function:
[-32767 -
View an extra description of the
error. This parameter is mostly used
with alarm 38, internal fault.
Function:
[0 -
View the time when the logged
event occurred. Time is measured in
s from frequency converter start-up.
Function:
[0 - 6]
View the frequency converter type.
The readout is identical to the FC
300 power field of the type code
definition, characters 1–6.
Danfoss A/S © 03/2019 All rights reserved.
VLT® AutomationDrive FC 361
15-41 Power Section
Range:
0
*
15-42 Voltage
Range:
0
*
15-43 Software Version
Range:
0
*
15-44 Ordered Typecode String
Range:
0
*
15-45 Actual Typecode String
Range:
0
*
15-46 Frequency Converter Ordering No
Range:
0
*
15-47 Power Card Ordering No
Range:
0
*
15-48 LCP Id No
Range:
0
*
15-49 SW ID Control Card
Range:
0
*
Function:
[0 - 20]
View the frequency converter type.
The readout is identical to the FC
300 power field of the type code
definition, characters 7–10.
Function:
[0 - 20]
View the frequency converter type.
The readout is identical to the FC
300 power field of the type code
definition, characters 11–12.
Function:
[0 - 5 ]
View the combined SW version (or
package version) consisting of
power SW and control SW.
Function:
[0 - 40 ]
View the type code string used for
reordering the frequency converter
in its original configuration.
Function:
[0 - 40 ]
View the actual type code string.
Function:
[0 - 8 ]
View the 8-digit ordering number
used for reordering the frequency
converter in its original configu-
ration. To restore the ordering
number after the power card
exchange, see
parameter 14-29 Service Code.
Function:
[0 - 8 ]
View the power card ordering
number.
Function:
[0 - 20 ]
View the LCP ID number.
Function:
[0 - 20 ]
View the control card software
version number.
MG06J202