Secton 6 - Electrcal System
•
Display reads CODE 0000
6.
Press up and right arrow to enter code 2222, Press Enter.
•
Display reads ACCESS LEVEL 2.
•
On later models, the display may continue to read "ACCESS LEVEL 3". Repeat step b. and
enter code 1775.
7.
Press Right Arrow to SETUPS, Press Enter.
•
Display reads CHANGE DEFAULTS
8.
Press Right Arrow to LOAD SETUPS. Press Enter.
•
Display reads CALIBRATE LOAD
9.
Press Enter.
•
Display reads PLATFORM DOWN? Verify that platform is fully lowered.
10.
Press Enter.
•
Display reads PLATFORM LOADED? Verify that rated load is in platform.
11.
Press Enter.
•
Display reads PLEASE LIFT.
12.
Hold lower controls switch in the up position until machine is fully elevated, then release switch.
•
Display reads PLEASE LOWER.
13.
Hold switch in down position until platform is in the fully lowered position. Release switch.
•
Display reads PLATFORM LOADED?
14.
Ensure that the rated load is distributed evenly in the platform, then press Enter.
•
Display reads PLEASE LIFT.
15.
Hold lower controls switch in the up position until machine is fully elevated, then release switch.
•
Display reads TOTAL DATA #XX, then PLEASE LOWER.
Note:The platform will rise incrementally during this phase on the calibration. Do not release the
switch until fully elevated.
16.
Hold switch in down position until platform is in the fully lowered position.
Note:The platform will lower incrementally during this phase on the calibration. Do not release the
switch until fully lowered.
17.
Release switch.
•
Display reads TOTAL DATA #XX, then PLATFORM EMPTY?
18.
Remove the load from the platform.
Note:If you must switch to platform controls to move the machine, steps 1.] through 7.] must be
repeated. Steps 12.] through 20.] will generate the REDO prompt. Answer NO. If machine was
not moved, proceed to step 22.].
19.
Press Enter.
•
Display reads PLEASE LIFT.
20.
Hold lower controls switch in the up position until machine is fully elevated, then release switch.
•
Display reads TOTAL DATA #XX, then PLEASE LOWER.
21.
Hold switch in down position until platform is in the fully lowered position.
•
Display reads TOTAL DATA #XX, then BUILDING TABLES, then CALDATE mm/dd/yy.
22.
Enter current date using Up, Down and Right Arrows.
•
Display reads FINISHED.
23.
Disconnect EZ-Cal.
Page 62