Secton 8 - Troubleshootng - 3084RT Models
Operation
ID
5F-1
5F-2
5F-3
5F
5F-4
OUTRIGGERS
5F-5
Called "Outriggers"
5F-6
on the EZ-Cal,
5F-7
these personalities
effect Auto-level
5F-8
function
5F-9
5F-10
5F-11
5G-1
5G
5G-2
GROUND MODE
5G-3
5G-4
Lower Control
5G-5
Operations
5G-6
5H-1
5H-2
5H
TILT
5H-3
5H-4
TILT 2
5H-4
5H-5A
Sub Menu
5H-5B
5H-5C
5I-1
5I
OVERLOAD
5I-2
5I-3
ANSI: values = 0
5I-4
CE: values apply
5I-5
5I-6
5I-7
OVERLOAD 2
5I-8
5I-8a
Sub Menu
5I-8b
5J-1
5J
5J-2
ALARMS
5J-3
5K-1
5K-2
5K-3
5K-4
5K
HEIGHTS
5K-5
5K-6
5K-7
5K-8
Page 98
Personality
Factory Setting
Outriggers
Extend
Level
Retract
Debounce
Initial
Tilt filter
X Tilt target
0.2 deg
Y Tilt target
0.2 deg
Tilt Slack
0.3 deg
Outrigger Test
Yes/No
UP
DOWN
OUT
IN
ACCEL
1.0 sec
DECEL
1.0 sec
X Trip
2.0 degrees
Y Trip
2.0 degrees
Delay Trip
2.0 sec
Delay Clear
0.5 sec
Tilt 2
At Height
X Trip 2
1.5 sec
Y Trip 2
1.5 sec
Trip @
ANSI: 0%
Lamp @
ANSI: 0%
Alarm @
ANSI: 0%
@ Height
ANSI: 0%
Safe Down
ANSI: 0%
Delay Trip
1.5 sec
Delay Clear
1.5 sec
Overload # 2
@ Height
Scale
Drive: Yes/No
Lift
2 = Down
Tilt
1 = When Elevated
Elevation
Maximum Drive
Maximum Lift
ANSI: 101%
Armguard
Overload
ANSI: 0%
Safe Down
ANSI: 0%
Overload # 2
Tilt # 2
ANSI: 0%
Speed Level Seres - Servce & Parts Manual
2
Not Used
50%
O/R speed before all legs down
35%
O/R speed after all legs touch down
55%
Maximum speed potential
0.35
Compensates for switch bounce
0.5
Not Used
6
Compensates for tilt sensor free movement
Target level stops movement
Target level stops movement
Additional compensation
Not Used
53%
Maximum speed potential
0%
Gravity down
0%
Power deck operation (not used)
0%
Power deck operation (not used)
Ramp-up time to maximum
Ramp-down drive output
Angle tilt sensor signals Out Of Level
Angle tilt sensor signals Out Of Level
Time delay between Tip and Signal
Time delay between Tip and Signal OFF
-
Sub category, press ENTER to access
101%
Point where lesser tilt angle used
Not Used
Not Used
CE: 110%
% of weight over maximum to trigger overload
CE: 0%
% of weight over maximum to trigger lamp
CE: 0%
% of weight over maximum to trigger alarm
CE: 8%
% of elevation load sense starts monitoring weight
CE: 12%
% of elevation lift-down still operates in overload
Delay before overload trip
Delay before overload clear
-
Sub category, press ENTER to access
0%
% of height for secondary overload valve
100%
% of reduced overload valve
No
1 = FWD
1 = UP
1 = When Elevated
15%
Point at which machine enters elevated mode
101%
Maximum drivable height
CE: 98%
Maximum elevated height potential
101%
Stops descent for 5 sec
CE: 8%
% of elevation load sense starts monitoring weight
CE: 12%
% of elevation lift-down still operates in overload
0%
Not Used
CE: 0%
Reduced degree of tilt at % elevation
January 2019
Explanation
2 = REV
3 = Both
4 = All Motion
2 = DOWN
3 = Both
4 = All Motion
2 = Always
Need help?
Do you have a question about the Speed Level Series and is the answer not in the manual?
Questions and answers