Mec Speed Level Series Service & Parts Manual page 137

Table of Contents

Advertisement

Secton 9 - Troubleshootng - 3084ES Models
DIAGNOSTIC
Use in conjunction with
Diagnostic tables for
Thorough explanation
Of personalities and values
2A
SYSTEM
ENTER
2A-1
2A-2A
MODE
PRESS ENTER
SUPPLY
FOR MESSAGES
BATTERY VOLTS
2A-2
2A-2B
SUPPLY
SUPPLY
12 VOLT SUPPLY
ENTER
2A-2C
2A-3
VALVE SUPPLY
SUPPLY
CAP BANK
ON/OFF
2A-2D
2A-4
MOTOR VOLTS
SUPPLY
ACTUAL
BATT SCALE
2A-5
MOTOR AMPS
ACTUAL
2A-6
TEMPERATURE
2A-7A
OF P600
CONTROLLER
TILT FILTERED
2A-7
NOT USED
TILT
2A-7B
TILT LOCAL
ENTER
GP400 LEVEL
2A-8
TILTED
2A-9A
YES OR NO
HEIGHT 1
2A-9
ANSI & CE
HEIGHT
ACTUAL IN %
2A-9B
ENTER
HEIGHT 2
CE ONLY
2A-10
LOAD
OVERLOAD
PROTECTION ONLY
2A-15A
2A-11
AXLE
OVERLOADED
ANSI & CE
YES or NO
2A-15B
2A-12
AXLE LOCKED
LAST MOVED
YES OR NO
NOT USED
2A-15C
2A-13
AXLE ANGLE
ELEVATED
IN DEGREES
YES or NO
2A-14
OUTRIGGERS
AUTO-LEVEL INFO
2A-16A
2A-15
GEN DEB
AXLE
ENTER FOR INFO
2A-16B
ENTER
GEN RPM
2A-16
GEN STATE
2A-16C
HYBRED OPTION
ENTER
GEN RMS
PRESS ENTER
Page 130
XX84RT SERIES ANSI & CE
ENTER
2B
2C
GROUND
PLATFORM
ENTER
ENTER
2B-1
2C-1
TRIGGER
UP
ON/OFF
ON/OFF
2B-2
2C-2
DLD
DOWN
ACTUAL
ON/OFF
2B-3
2C-3
JOYSTICK
OUT
ACTUAL DEG OF
NOT USED
MOVEMENT
2B-4
2C-4
FWD / UP
IN
FWD JOYSTCK
NOT USED
MOVEMENT
2B-5
REV / UP
REV JOYSTICK
MOVEMENT
2B-6
LEFT(STEER)
ON/OFF
2B-7
RIGHT (STEER)
ON/OFF
2B-8
POSITRACK
ON/OFF
2B-9
ENTER
AUTO-
POSITRACK
2B-10
ON/OFF
AIRTRAX
NOT USED
2A-16C1
ENTER
TRMS
Speed Level Seres - Servce & Parts Manual
EZ-CAL MENU
2
DIAGNOSTICS
2D
2E
ANALOGS
INPUTS
ENTER
ENTER
2D-1
2E-1
P7-1
GP400 ANALOGS
MAIN CPU
12 V SUPPLY
ENTER
2D-2
2E-1A
P7-2
P8-2
BASE SELECTED
ANGLE
TRANSDUCER 1
2D-3
2E-1B
P7-3
UP
P8-5
SELECTED
ANGLE
TRANSDUCER 2
2D-4
2E-1C
P7-4
PLATFORM
P8-6
SELECTED
PRESSURE
TRANSDUCER
2D-5
2E-1D
P7-7
P8-9
DOWN SELECTED
TBM IN
2D-6
P7-10
2E-2
ENG PRE-HEAT
MATRIX
ANALOGS
2D-7
UPPER CONTROL
P7-12
ENTER
ENG START
2E-2A
2D-8
M2-6
POTENTIOMETER
P7-13
ENG OIL PRESSURE
NOTE: All other plug numbers shown on the EZ-cal
but not listed here are not used on this model
January 2019
EZ-Cal Flow Chart
SYMBOL
KEY FUNCTIONS
ESC/ENTER BUTTONS
To move back and forth between
Menu and sub-menu
LEFT/RIGHT BUTTONS
Select menus and setting to be adjusted
UP/DOWN BUTTONS
Adjust setting values
2F
OUTPUTS
ENTER
2F-1
2F-10
P5-6
P4-1
ALARM
CHOKE, PREHEAT
2F-2
2F-11
P4-2
P5-9
STARTER
HOUR METER
2F-3
2F-12
P4-4
P5-14
THROTTLE
STRT INHIBIT
LIGHT
2F-4
2F-13
P4-7
P6-1
ALTERNATOR
LEVEL BACK
EXCITE
2F-5
2F-14
P4-8
P6-2
IGNITION,
LEVEL FORWARD
FUEL
2F-6
2F-15
P4-14
P6-3
DOWN VALVE
LEVEL RIGHT
2F-7
2F-16
P5-1
P6-4
LIFT VALVE
LEVEL LEFT
2F-8
2F-17
P5-2
P6-13
STEER RIGHT
AXLE LOCK
2F-9
2F-18
P5-3
P6-15
STEER LEFT
A/C GENERATOR
BOOM GP400
ALL CIRCUITS 12V
ONLY
2G
LOG
ENTER
2G-1
CALDATE
DATE OF
CALIBRATION
2G-2
SOFTWARE
SOFTWARE
VERSION NUMBER
2G-3
POWERED
ACCUMULATED
HRS ON GP400
2G-4
MAX BATTERY
HIGHEST BATT
VOLTAGE