3.1

Requirements

Prepare the power supply, the air supply, and the grounding according to the following
specifications.
No.
Item
Power supply
1
Air supply
Spray ON/OFF
Gun-tilt switching
Pressurized explo-
sion proof enclosure
2
Grounding
3
Use dry air for the pressurized explosion-proof enclosure. Moisture in the air supply may
damage the electronic parts.
Table 3-1 Specifications
Specifications
3-phase 200/220 VAC
(±10 % to -15 %)
50/60 Hz (±2 Hz)
5 kVA (at peak)
Required pressure: 0.35 MPa to
0.65 MPa
Capacity:
For turning the spray ON/OFF:
30 N/min
For switching the tilt of the gun:
30 N/min
For the pressurized explosion proof
30 N/min usually
1000 N/min when purging
Dryness: Freezing at -18°C
Grounding resistance:
100 ohm or less (Non I.S. GND)
10 ohm or less (I.S. GND)
CAUTION
3-1
3 Installation
3.1 Requirements
Remarks
(Option)
3-phase 240/480/575VAC
(+10% to -15%)
50/60 Hz (±2 Hz)
5 kVA
Use dry air for the
pressurized explosion-
proof construction.
For the robot controller
HW0485080