Maintenance
Replacement Procedures
High Limit Thermostats
Removal
Be sure oven is disconnected from branch circuit power
before performing any repair work.
1. Turn off oven power and disconnect oven from the branch circuit.
2. Remove back cover and right side panel.
3. For the CC10-E, remove the L-cover.
4. Fold back insulation as necessary to gain access to the thermostat probe.
Disconnect any electrical wiring necessary for the removal of the capillary and
probe.
5. Loosen thermostat probe clip. Slowly and carefully pull thermostat probe from
the clip.
6. Check if thermostat electrical wire labels TC1 and TC2 are legible. If
necessary, refer to the schematic diagram, and identify and label the wires.
7. Disconnect wires TC1, TC2 and jumper wire from the thermostats.
8. Remove thermostats and thermostats mounting bracket as an assembly from
the oven.
9. Remove thermostat(s) from the bracket.
Installation
1. Install thermostat(s) on mounting bracket.
2. Install thermostat and mounting bracket assembly.
3. Route capillary to the probe kit. Be sure to stay away from any electrical
connections and not to make any sharp bends in the capillary.
4. Insert thermostat probe into the probe clip and tighten clip.
5. Connect any heating element and temperature probe electrical wiring that was
disconnected during removal.
6. Put insulation back into place.
7. Connect wires TC1, TC2, and jumper wire to thermostat terminals.
8. For the CC10-E, install the L-cover.
9. Install the back and right hand side covers.
10. Connect oven to the branch circuit.
8-26
WARNING
(Revised 1/02)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CC20-E and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Cc10-eC/2gCc10-gCc20-gC/2-e

Table of Contents

Save PDF