Maintenance
Replacement Procedures
Drain Temperature Probe
Prior to Serial Numbers GC7243MS and C7439MS
Removal
Be sure oven is disconnected from branch circuit power
before performing any repair work.
1. Turn off oven power and disconnect oven from the branch circuit.
An incorrectly installed drain temperature probe MUST be replaced.
A bent drain temperature probe will cause improper oven operation.
2. Remove back cover from oven.
3. Disconnect drain temperature probe electrical leads from probe
harness.
4. Loosen probe compression nut.
The probe fitting may turn with the compression nut. If this shoul
happen, remove fitting with the probe and compression nut. The
probe and compression nut are an assembly.
5. Remove drain temperature probe. If male fitting was removed
with the probe and compression nut, remove it from the probe.
If probe is bent, it must be replaced.
Installation
Be sure oven is disconnected from branch circuit power
before performing any repair work.
1. If male fitting was removed with the probe and compression nut,
install it at this time.
2. Install a NEW compression nut and drain temperature probe. Be
careful not to bend the probe. Be sure probe is fully inserted into
drain pipe and that tip of probe does not touch drain pipe.
3. Connect probe wires to probe harness.
4. Install back cover.
8-18
(Old Electronics Only)
WARNING
NOTICE
IMPORTANT
WARNING
(Revised 1/02)
Need help?
Do you have a question about the CC20-E and is the answer not in the manual?