Maintenance
Replacement Procedures
Water Level Probe
Removal
Be sure oven is disconnected from branch circuit power before
performing any repair work.
1. Turn off oven power and disconnect oven from the branch circuit.
2. Remove right side cover from oven.
3. If identification is missing from the probe electrical leads, identify and
mark them at this time.
4. Disconnect electrical lead from water level probe being removed,
then carefully remove probe. Be careful not to damage the probe
ceramic material.
5. Clean the probe and the probe holder.
6. Inspect probe and probe ceramic for damage. If damaged, replace
probe.
7. Measure length of water level probe. Length of probe must be
4-15/16 inches from the tip to the bottom of the hex. See the
following illustration.
8. If probe length is greater than 4-15/16 inches, cut to correct length
using a hacksaw.
9. If probe length is shorter than 4-15/16 inches, replace the probe.
Installation
Be sure oven is disconnected from branch circuit power before
performing any repair work.
1. Apply a thin film of nontoxic, FDA approved pipe sealant to the
threads of the water level probe.
2. Slowly and carefully install probe into probe holder and securely
tighten probe by turning on the probe hex nut.
3. Correctly connect electrical lead to probe.
4. Install oven side cover.
5. Connect oven to the branch circuit.
8-12
WARNING
WARNING
(Revised 1/02)