Probable Cause
Leaks around water inlet valve.
Cracked water inlet valve housing.
Leaks around heating elements and
boiler water inlet fittings.
Probable Cause
Conditions required to turn on spray:
Steam Mode - Door closed, and timer operating or boiler water ready and drain hot.
Combo Mode - Door closed and boiler water at ready temperature.
No condensate spray.
(Revised 1/02)
Be sure oven is disconnected from branch cir-
cuit power before performing any repair work.
Replace garden hose gasket. See page 8-25.
Tighten hose clamp, but do not overtighten.
Replace a damaged hose.
Replace valve. See page 8-27.
Tighten mounting nuts.
Replace fiber washers. See page 8-49.
PROBLEM: IMPROPER CONDENSATE SPRAY OPERATION
When oven power is turned on, there is high
voltage present in the electrical components
compartment.
Test water inlet valve. See page 8-6.
24VAC measured. Inspect spray nozzle for blockage. If
necessary, clean nozzle.
24VAC not measured. Measure voltage between K14
contacts.
TROUBLESHOOTING
PROBLEM: WATER LEAKS
Corrective Action
WARNING
Corrective Action
WARNING
7-17