Peripheral Equipment - Sony PCM-3348HR Operation Manual

Digital audio recorder
Hide thumbs Also See for PCM-3348HR:
Table of Contents

Advertisement

Using the synchronizer event control
function
This section describes the procedure to set the
synchronizer event control function so that the REC
command signal is output at the punch in point, and
the PLAY command signal at the punch out point.
1
Connect the rehearsal status command output of
the synchronizer to pin No. 20 of the PCM-
3348HR REMOTE-1 connector.
2
Produce the logical sum (OR) of the synchronizer
event output and the tape transport output REC
command signal, and connect to pin No. 36 of the
PCM-3348HR REMOTE-1 connector.
3
Produce the logical sum (OR) of another
synchronizer event output and the tape transport
output PLAY command signal, and connect to pin
No. 37 of the PCM-3348HR REMOTE-1
connector.
4
Select the rehearsal function on the synchronizer.
5
Set the punch in and punch out points on the
synchronizer.
6
Using the synchronizer event control function, set
the trigger address.
1) Set the event 1 trigger address (the event output
connected in step 2 above) as the in point.
2) Set the event 2 trigger address (the event output
connected in step 3 above) as the out point.
3) Start the synchronizer event control function.
For details of synchronizer settings and operations, refer to
the synchronizer Operation Manual.

11-1-4 Peripheral Equipment

DMU-3048 Digital Meter Unit
This is a peak meter, capable of displaying the levels
of 48 digital audio channels. It also has out-of range,
recording (REC) and recording enabled (REC
READY) indications, and a peak hold and
functions.
You can use this meter to monitor the status of all 48
digital audio channels from a remote location.
Chapter 11 System Configuration
calibration
11-5

Advertisement

Table of Contents
loading