Sony PCM-3348HR Installation Manual

Digital audio recorder / converter board pack
Hide thumbs Also See for PCM-3348HR:

Advertisement

Quick Links

DIGITAL AUDIO RECORDER
PCM-3348HR
CONVERTER BOARD PACK
DABK-3343HR
INSTALLATION MANUAL
1st Edition (Revised 1)
PCM-3348HR Serial No. 10001 and Higher
DABK-3343HR Serial No. 10001 and Higher

Advertisement

Table of Contents
loading

Summary of Contents for Sony PCM-3348HR

  • Page 1 DIGITAL AUDIO RECORDER PCM-3348HR CONVERTER BOARD PACK DABK-3343HR INSTALLATION MANUAL 1st Edition (Revised 1) PCM-3348HR Serial No. 10001 and Higher DABK-3343HR Serial No. 10001 and Higher...
  • Page 2 ! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
  • Page 3: Table Of Contents

    Installation of the DABK-3343HR ............1-14 1-9. Installation of the Shield Panel (For CE only) .......... 1-14 2. Periodic Inspections and Maintenance 2-1. Daily Maintenance PCM-3348HR .............. 2-1 2-1-1. Cleaning ..................2-1 2-1-2. Magnetic erasing on the heads ........... 2-1 2-1-3.
  • Page 4: Manual Structure

    Manual Structure Purpose of this manual This manual is the Installation Manual of the Digital Audio Recoder PCM-3348HR and Converter Board Pack DABK-3343HR. This manual is intended for use by trained system and service engeineers, and describes the information when installing.
  • Page 5: Installation

    Ventilation/Radiation RM-3348HR: 0.7A PCM-3348HR has the fan to cool the entire unit. If the intake on the fan is blocked, or the fan stops rotating, the unit may be damaged. Therefore, there must be at least 20 cm of clearance at the rear of the nuit.
  • Page 6: Ac Power Cord

    1-2. Power Supply 1-2-2. AC Power Cord The PCM-3348HR includes the appropriate AC power cords for each destination of the PCM-3348HR and RM-3348HR. PCM-3348HR RM-3348HR For UC For UC 5000±100 Power cord Unit: mm For CE For CE 5000±100 Power cord...
  • Page 7: Installation Space

    1-3. Installation Space 1-3. Installation Space 1-3-1. PCM-3348HR (1) Dimensions Unit: mm (2) Working space Mecha deck Extension board EXT-310 Extention board EXT-309 RM/DIO rack Connector panel Switching regulator Unit: mm PCM-3348HR...
  • Page 8 1-3. Installation Space 1-3-2. RM-3348HR (1) Dimensions (Remote control unit) Unit: mm (2) When the remote control unit is installed to the remote stand. 32° 20° 5° 10° Unit: mm PCM-3348HR...
  • Page 9: Installing The Remote Control Unit On The Remote Stand

    Screw +B4 x 8: Screw +PSW4 x 14: 4 Top plate Cord clamper: Spring washer M5 x 12 Plane washer (2pcs) Nylon washer(2pcs) Knob bolt (M8 x 45) Cord Knob bolt clamper M8 x 20(2pcs) Slider Leg assy Caster PCM-3348HR...
  • Page 10: Installation Of The Remote Unit On The Remote Stand

    (3) Secure the remote cable connecting the remote unit to the recorder with the cord clamp located at the bottom of the top plate. Cord clamper Top plate Remote cable 2 Lock. 1 Insert the remote cable. PCM-3348HR...
  • Page 11 3 Lock. (Supplied) Leg assy Power cord Wire stopper Cord clamper +B4 x 8 Assembled Unit (5) Secure the power cord with the cord clamp located at the bottom of the top plate. Cord clamper 2Lock. 1Insert the remote cable. PCM-3348HR...
  • Page 12: Angle Adjustment Of The Ac Control Panel

    Loosen the right and left angle adjustment knob bolt and Lock lever adjust the angle of the top plate. Then, fasten the angle adjustment knob bolt to secure the top plate. Knob bolt for angle adjustment Top plate Slider PCM-3348HR...
  • Page 13: Installation Of The Dio-43 Board (Supplied)

    DIO-43 board, fix the DIO-43 board. After the installing has been completed, switch setting and adjustments are not required. Turn the power of PCM-3348HR off befor removing or inserting boards. Procedure (1) Loosen the two fixing screws (right and left screws) of the DIO-46 board.
  • Page 14: Using The Extension Board

    D rack boards. DET-28, DAP-14, MC-53, TCR-7, CTK-15, ARP-5, MEM-68, ED-50, ED-40, ED-41, MT-128, CK-30, DAD- 30, SV-163, SVD-15 Turn the power of PCM-3348HR off before removing or inserting boards. Procedure (1) Open the front door. (2) Loosen the two screws of the board to be extended.
  • Page 15: Using Extension Board Ext-309

    DIO-41, DIO-42, DIO-44, DIO-45, DIO-46, IF-321, IF- 324, IF-326, IF-327, DIO-43 (Supplied) Turn the power of PCM-3348HR off before removing or inserting boards. Procedure (1) Loosen the two screws (right and left screws) of the...
  • Page 16: Connector/Cable

    Sony part number DIGITAL AUDIO CHANNEL LINE INPUT CH-1 to CH-48 Multi connector Multi connector 1-565-704-11 27P, female 27P, male Supplied with PCM-3348HR DIGITAL AUDIO CHANNEL LINE OUTPUT CH-1 to CH-48 Multi connector Multi connector 1-565-705-11 27P, male 27P, female...
  • Page 17 IEEE-488 Interface cable Optional accessory female SMK-0032 TAPE RECORDER D-sub 50P, male Connection cable (remote) 1-557-378-12 Supplied with PCM-3348HR Phone jack (6 φ) Phone plug (6 φ) SOUND MEMORY EXT TRIGGER IN — DMU-3024S POWER SUPPLY DIN 6P, socket DIN 6P, plug —...
  • Page 18: Installation Of The Dabk-3343Hr

    (For CE only) The DABK-3343HR comprises the following; DAD-30 board:12 Since the shield cover is attached to the PCM-3348HR CE model in order to satisfy the performance of unit under the Turn OFF the POWER switch of PCM-3348HR. heavy electromagnetic field.
  • Page 19: Periodic Inspections And Maintenance

    Periodic Inspections and Maintenance 2-1. Daily Maintenance PCM-3348HR 2-1-3. Dust Cover Handling In order to maintain the performance of the PCM-3348HR, The dust cover prevents foreign matters entering PCM- perform cleaning and head erasing every day. 3348HR through the air duct. If the filter (refer to the following figure) of the dust cover is clogged, the cooling 2-1-1.
  • Page 20: Periodic Inspections

    The number of hours (OOO H) will be In digital audio recorders like the PCM-3348HR that are displayed in the TAPE TIME display section. protected by error correction systems, minute defects in The schedule of implementing the periodic inspection system components do not become readily apparent.
  • Page 21 2-2. Periodic Inspections Table 1 PCM-3348HR periodical check items Perform the periodic inspection as shown in the following table after a certain number of hours since start of use has elapsed. Readjust the electromagnetic conversion system to correct the head wear that occures between each periodic inspection, confirm the DAD characteristics and replace any defective parts.
  • Page 22 4. Check the ARP recording and playback. 5. Check the DAD characteristics. 1 Measure the noise ratio. 2 Measure the frequency characteristics. 3 Measure the distortion rate. Mechanical section 1. Punch in/out functions. 2. Function control system. 3. Shuttle function. PCM-3348HR...
  • Page 23 The material contained in this manual consists of screws, and all other exposed metal parts for AC information that is the property of Sony Corporation and leakage. Check leakage as described below. is intended solely for use by the purchasers of the equipment described in this manual.
  • Page 24 Printed in Japan Sony Corporation PCM-3348HR (UC, CE) E 1998. 12 08 Broadcasting & Professional Systems Company ©1997 3-192-592-02...