Switch settings
PCM-3348HR settings
Switch
Master unit
REC MODE
INSERT
SYNC CLOCK
VIDEO
Fs
Set automatically
REFERENCE
When terminated: ON
VIDEO INPUT
For loop-through
75Ω
output: OFF
TIME CODE
EXT
selection
TIME CODE GEN Format being used
format selection
RM-3348HR settings
Switch
Master unit
SELECTOR
ON (MASTER)
switch No.2 (lower)
SELECTOR switch No.4: OFF
No.4 to 8 (lower)
No.5: OFF
No.6: OFF
No.7: OFF
No.8: OFF
Device address:
00H
SLAVE button
OFF
Timer display mode CTL ABSOLUTE
or CTL RELATIVE or CTL RELATIVE
Notes on operation
The master PCM-3348HR, the video equipment, and
the time code synchronizer are all synchronized to a
composite video signal.
The slave PCM-3348HR is synchronized to the
master unit by the word sync signal. The two PCM-
3348HR units must therefore have the same sampling
frequency.
Use cables with BNC connectors to connect the word
sync, sector sync and sector address signals.
By setting the VARI SYNC switch on the MC board
of the master PCM-3348HR unit to ON, you can use
the variable speed playback function to control the
tape transport on both the master
Use a prestriped tape and carry out insert recording.
The tape on the slave unit must be prestriped with the
same sampling frequency as the master unit.
Slave unit
INSERT
Set automatically
Set the same as
the master unit
Slave unit
OFF (SLAVE)
No.4: OFF
No.5: OFF
No.6: OFF
No.7: OFF
No.8: ON
Device address:
01H
ON
CTL ABSOLUTE
and slave units.
Chapter 11 System Configuration
11-23