Switch settings
PCM-3348HR settings
Switch
Master unit
REC MODE
INSERT
SYNC CLOCK
VIDEO
Fs
Set automatically
REFERENCE
When terminated: ON
VIDEO INPUT
For loop-through
75Ω
output: OFF
TIME CODE
EXT
selection
TIME CODE GEN Format being used
format selection
RM-3348HR settings
Switch
Master unit
SELECTOR
ON (MASTER)
switch No.2 (lower)
SELECTOR switch No.4: OFF
No.4 to 8 (lower)
No.5: OFF
No.6: OFF
No.7: OFF
No.8: OFF
Device address:
00H
SLAVE button
OFF
Timer display mode CTL ABSOLUTE
or CTL RELATIVE or CTL RELATIVE
Notes on operation
•
The master PCM-3348HR, the video equipment, and
the time code synchronizer are all synchronized to a
composite video signal.
•
The slave PCM-3348HR is synchronized to the
master unit by the word sync signal. The two PCM-
3348HR units must therefore have the same sampling
frequency.
•
Use cables with BNC connectors to connect the word
sync, sector sync and sector address signals.
•
By setting the VARI SYNC switch on the MC board
of the master PCM-3348HR unit to ON, you can use
the variable speed playback function to control the
tape transport on both the master
•
Use a prestriped tape and carry out insert recording.
•
The tape on the slave unit must be prestriped with the
same sampling frequency as the master unit.
Slave unit
INSERT
Set automatically
Set the same as
the master unit
—
—
—
Slave unit
OFF (SLAVE)
No.4: OFF
No.5: OFF
No.6: OFF
No.7: OFF
No.8: ON
Device address:
01H
ON
CTL ABSOLUTE
and slave units.
Chapter 11 System Configuration
11-23