4-1-4 Muting the Monitor Signal

There are two methods for muting the monitor signal
for all digital audio channels.
Muting all monitor outputs regardless of whether
input or playback.
Muting only the playback monitor outputs.
S
REC MUTE
REC
1
2
REC
READY
REPRO
INPUT
1
2
Muting the monitor output from all
channels
Press and light the ALL MUTE button.
The REPRO buttons and INPUT buttons for all digital
audio channels go off, and the monitor signal for all
digital audio channels set in the REPRO or INPUT
state is muted.
To exit the muted state, press the ALL MUTE button
again to turn it off.
SET UP MEMORY
REHEARSAL
2CH DIO
RECALL
(REC DISABLE)
SET UP
ENABLE
A
B
C
D
3
4
5
6
7
8
9
10 11 12 13 14 15 16
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Muting the monitor signal
ALL MUTE button
REPRO MUTE button
DIGITAL AUDIO REMOTE CONTROL UNIT RM-3348HR
MONITOR MODE CONTROL
ALL
ALL
ALL
REPRO
AUTO
X'FADE
STORE
INDIVIDUAL
REPRO
INPUT
MUTE
MUTE
INPUT
OUTPUT
17 18 19 20 21 22 23 24
17 18 19 20 21 22 23 24
Muting only the playback monitor outputs
Use the REPRO MUTE button, which is only active
when the tape transport is not in the recording state.
Pressing and lighting the REPRO MUTE button causes
the lit buttons for those channels to go off, and the
playback monitor signal for all those digital audio
channels is muted.
To exit the muted state, press the REPRO MUTE
button again, turning it off. Alternatively, pressing the
REC button and PLAY button to switch to the
recording state also releases the REPRO MUTE state.
Chapter 4 Basic Operations of the RM-3348HR Remote Control Unit