Executing Rcp Assignment From Equipment Other Than Msu - Sony BKP-7933 Installation Manual

S-bus interface board
Table of Contents

Advertisement

1-7. Setting Up

1-7-5. Executing RCP Assignment from Equipment Other Than MSU

Description of Operation
Set the menu as follows when you want to execute RCP assignment from equipment other than MSU.
When this setting is executed, a maximum of 96 x 96 CCU-RCP matrix can be set in the matrix space of
the S-BUS. The RCP assignment can be set from a remote control unit such as BKS-R3202. (However,
setting cannot be made across two or more CNUs.) The setup data of the RCP assignment that is made
here is saved in the BKP-7933 side.)
n
. The contents of the settings that are made using this menu are reflected in the "Setting status of the
control system" of the CNU-700 character display.
BVP-500/700/900 series
CNU 1
CNU 2
*
shows an area where the SOUCE No. and DESTINATION No. cannot be set.
1-22 (E)
CCU-700A
CCU-RCP MATRIX
(SOURCE No.)
CCU 1
(Top)
IN 1
(+1)
IN 2
(+2)
IN 3
CCU 12
(+11)
IN 12
CCU 13
(+12)
IN 13
(+13)
IN 14
(+14)
IN 15
CCU 24
(+23)
IN 24
(DESTINATION No.)
(Top) (+1) (+2)
RCP1
RCP-700 series
(+11)
(+12) (+13) (+14)
(+23)
RCP24
BKP-7933

Advertisement

Table of Contents
loading

Table of Contents