8-2-2 Copying via the MADI Connectors

Connections
Power off all units before making the connections.
PCM-3348HR
(recorder)
Procedure
Use the following procedure to copy the digital audio
signals.
1
Mount the original tape on the player unit, and set
the MASTER SAFE switch on the PCM-3348HR
system control block to the ON position.
2
Mount a blank tape on the recorder unit, and set
the switches and buttons as follows:
• MASTER SAFE switch: OFF
• REC MODE switch: ADVANCE
• TIMER MODE button: CTL ABSOLUTE
• Fs switch: sampling frequency of the original tape
• WORD LENGTH switch: word length of the
original tape
• INPUT SELECT switch: DIGITAL
• SDIF-2/MADI switch: MADI
• SYNC CLOCK switch: EXT
• TIME CODE selection switch: EXT or REGEN
(EXT)
A1
Analog audio signal
INPUT
A2
Analog audio signal
INPUT
TIME CODE
Time code signal
INPUT
MADI
Digital audio signal
INPUT
WORD SYNC
Word sync signal
INPUT
Connections for copying the digital audio signals only
A1
OUTPUT
A2
OUTPUT
TIME CODE
OUTPUT
MADI
OUTPUT
WORD SYNC
OUTPUT
• ALL CHANNEL REC READY button: ON
• A1 A2 REC READY button: ON
• TIME CODE REC READY button: ON
Check that the 2 CH DIO SET UP button on the
RM-3348HR is off when the RM-3348HR is
connected to the recorder.
3
On the recorder, set the CTL to the start point
address on the original tape.
4
Begin playback on the player.
5
On the recorder, holding down the REC button,
press the PLAY button.
This begins the copy process.