Parameter Unit

Parameter unit (FR-PU07)

 The parameter unit is a convenient tool for drive unit setting
such as direct input with a numeric keypad, operation status
indication, and help function.
 Parameter setting values of maximum of three drive units
can be stored.
 The parameter unit connection cable FR-CB20 is required for connecting to
the drive unit.
POWER lamp
ON when the power is supplied.
Monitor
ALARM lamp
Turns ON to indicate a drive unit alarm
occurrence.
Operation keys
(Refer to the table on the right.)
FR-PU07
Main functions
Function
Monitor
6 types of monitors appear by simply pressing
For PU operation mode and External/PU combined operation mode (Pr.79 ="3"), speed setting is available.
Speed
Settings are performed by the direct setting, which sets speed directly by
setting
speed continuously by
Parameter
Reading parameter and changing setting values are easily done. To change the setting value of an parameter, specify
Setting
the parameter number, or select a parameter from the functional parameter list.
FR-PU07 reads parameter settings of a drive unit, and stores three different parameter settings.
Batch copy
FR-PU07 can also copy the stored parameter setting to another drive unit of the same series, or verify its stored
parameter setting against the parameter setting stored in a drive unit.
Switching between External operation mode [EXT] and PU operation mode [PU] is easy.
Operation
Start/stop is enabled during PU operation mode and External/PU operation mode (Pr.79 ="3").
 Available function differs by the drive unit. Please refer to the instruction manual of the drive unit and the parameter unit.
25
Liquid crystal display
(16 characters
4 lines with backlight)
Interactive parameter setting
Trouble shooting guidance
Monitor (frequency, current, power, etc.)
.
Key
Description
Used for parameter setting.
Press to choose the parameter setting mode.
First priority monitor is displayed.
In the initial setting, the output frequency is displayed.
Operation cancel key
Used to display the function menu.
A variety of functions can be used on the function
menu.
Used to shift to the next item in the setting or
monitoring mode.
Used to enter a frequency, parameter number or set value.
to
Drive unit operates in the External operation mode.
Used to select the PU operation mode to display the
frequency setting screen.
· Used to keep on increasing or decreasing the
running frequency. Hold down to vary the frequency.
· Press either of these keys on the parameter setting
mode screen to change the parameter setting value
sequentially.
· On the setting screen, these keys are used to move
the cursor.
· Hold down
and press either of these keys to
advance or return the display screen one page.
Forward rotation command key.
Reverse rotation command key.
· Stop command key.
· Used to reset the drive unit when an alarm occurs.
· Used to write a set value in the setting mode.
· Used as a clear key in the all parameter clear or
alarm history clear mode.
· Used as a decimal point when entering numerical
value.
· Used as a parameter number read key in the setting
mode.
· Used as an item select key on the menu screen such
as parameter list or monitoring list.
· Used as an alarm definition display key in the alarm
history display mode.
· Used as a command voltage read key in the
calibration mode.
Description
.
to
, and the step setting, which sets