HP 8360 B Series User Manual page 72

Swept signal generator, including options 001, 002, 004, 006, and 008
Table of Contents

Advertisement

Note
1-44 Getting Started Advanced
When an HP 437B power meter is used to automatically enter the
correction data, the correction calibration routine automatically turns
off any active modulation, then re-activates the modulation upon
the completion of the data entry process. Therefore, the scalar pulse
modulation that is automatically enabled in a scalar measurement
system is disabled during an HP 437B correction calibration.
The user flatness correction array cannot be stored to a disk. You
must make sure that the array is stored in one of the eight internal
registers. Recalling a file from an HP 8757 disk will not erase the
current array; therefore you may recall an array from an internal
register, then recall an associated file from a disk.
For
this example, refer to menu map 5, POWER.
1.
The equipment setup shown in Figure 1-21 assumes that
you have followed the steps necessary to correctly level the
configuration. If you have questions about external leveling, refer
to "Externally Leveling the Swept Signal Generator".
2.
On the analyzer, press I-). Reset the analyzer and swept
signal generator to a known state.
Setup System Parameters
3.
On the swept signal generator, press FREQUENCY ISTART) @
frequency sweep of 2 to 20 GHz.
4.
Press
(
POWER
power.
5.
On the analyzer, set up the appropriate measurement
(i.e. gain for an amplifier). Calibrate the measurement (thru and
short/open calibration). Press ISAVE) 0 to store the analyzer's
configuration and swept signal generator parameters in storage
register 1.
6.
Turn off the HP 8757 System Interface. Use the analyzer
SYSINTF ON OFF softkey found under the SYSTEM menu to
deactivate the system interface.
Access User Flatness Correction Menu
7.
On the swept signal generator, press POWER (MENU). Select
Fltness Menu.
8.
Select Del.ete Menu Delete All. This step insures that the
flatness array is empty.
9.
Press (PRIOR). Leave the delete menu and return to the previous
soft key menu.