List Mode Pt Trighuto - HP 8360 B Series User Manual

Swept signal generator, including options 001, 002, 004, 006, and 008
Table of Contents

Advertisement

List
Function Group
Menu Map
Description
Programming Codes
See Also
L-8 Operating and Programming Reference
LIST[:POWer]:CORRection:POINts? [MAXimumlMINimum]
In the above three commands, the swept signal generator responds
with the number of points for the named parameter that are in the
list array.
If a particular list is shorter than another, an error is generated upon
execution. An exception is made for the case where the shorter list
is of length 1. In this case, the list of length 1 is treated as though
it were a list of equal length, with all values the same. At *RST, all
lists for the current state are cleared and reset to a single value.
Analyzer:
NONE
"Creating and Using a Frequency List" in Chapter 1
FREQUENCY
2
This softkey lets you set the swept signal generator to automatically
step through a frequency list, when the swept signal generator is in
sweep list mode.
SCPI:
LIST:TRIGger:SOURce IMMediate
Analyzer:
NONE
List
Menu, Pt Trig Menu, Sweep Mode List