MODULATION
This softkey lets you set the swept signal generator to apply a slow
rise pulse filter to both internal and external pulse waveforms. This
results in pulses having approximately 2 ps rise/fall times. An
asterisk next to the key label indicates that this function is active.
SCPI:
PULM:SLEW <num>[time suffix]MAXimum
Analyzer:
NONE
Pulse Menu
4
This softkey lets you set a value for the internal pulse generator's
pulse width. The range of acceptable values is from 1 11s to 65.5 ms.
The factory preset value is 1 ms. When this feature is active, its
current value is displayed in the active entry area.
SCPI:
PULSe:INTernal:WIDTh <num>[time suffix] or
Analyzer:
NONE
Operating and Programming Reference P-23