19.3 Internal Registers of IEBus Controller
19.3.1 Internal register list
Address
Function Register Name
FFFFF3E0H
IEBus control register
FFFFF3E2H
IEBus unit address register
FFFFF3E4H
IEBus slave address register
FFFFF3E6H
IEBus partner address register
FFFFF3E8H
IEBus control data register
FFFFF3EAH
IEBus telegraph length register
FFFFF3ECH
IEBus data register
FFFFF3EEH
IEBus unit status register
FFFFF3F0H
IEBus interrupt status register
FFFFF3F2H
IEBus slave status register
FFFFF3F4H
IEBus communication success
counter
FFFFF3F6H
IEBus transmit counter
FFFFF3F8H
IEBus clock selection register
FFFFF3DEH
IEBus high-speed clock selection
register
Note The IEHCLK register is available only in the V850/SB2.
560
CHAPTER 19
IEBus CONTROLLER (V850/SB2)
Table 19-7. Internal Registers of IEBus Controller
Symbol
BCR
UAR
SAR
PAR
CDR
DLR
DR
USR
ISR
SSR
SCR
CCR
IECLK
Note
IEHCLK
User's Manual U13850EJ6V0UD
R/W
Bit Units for Manipulation
1 Bit
8 Bits
√
√
R/W
–
–
–
–
R
–
–
√
R/W
–
√
–
√
–
√
√
R
√
√
R/W
√
√
R
√
–
√
–
√
R/W
–
√
R/W
–
After Reset
16 Bits
–
00H
√
0000H
√
√
–
01H
–
–
00H
–
–
–
41H
–
01H
–
20H
–
00H
–
00H