7Appendix
Adjustment method
Vector product operation
(P×P)
To use the position adjustment function, click the menu [Tool] → [Position adjustment]. The Position adjust-
ment screen opens when [Position adjustment] is clicked.
Fig.7-105:Position adjustment screen
The position is adjusted with the following steps.
(A) The path point data for the Spline File Edit screen currently active is displayed in the "Adjustment tar-
get list". Select and check the path point data for which the position is to be adjusted. Multiple path
point data items can be selected.
Appendix-672 Spline interpolation
The adjustment data values are multiplied in respect to the path point data's robot position data.
(Position after adjustment = Path point position × adjustment data)
The adjustment follows the tool coordinate system.
The configuration flag, multi-rotation flag and additional axis data are not changed from the original
value.
PB
Yw
PA: Path point for adjustment target
PA:補正対象の経路点
PB: Adjustment results
PB:補正結果
PC: Adjustment data
PC:補正データ
Xt-Yt: Orientation of tool coordinates at PA
Xt-Yt:PAにおけるツール座標の向き
Vector product calculation (P×P)
ベクトル積演算(PxP)
Explanation
Xw
PA
(A)
(B)
(C)
(D)
(E)