Dedicated input/output

The functions shown in
parallel input/output unit by assigning the signal No. in the parameter.
The signal No. is assigned by the signal No. used in the order of "input signal" and "output signal" in each
parameter. Refer to
a "-1" is designated for the assigned signal No., that signal will be invalidated.
The I/O parameters can be set on the T/B parameter screen or by using the maintenance tool of the PC sup-
port software (optional). And refer to
To use the dedicated I/O signals, set the controller mode to AUTOMATIC, and turn on the operation rights
input signal (IOENA) beforehand.
Table 6-6:Table of dedicated input/output
Parameter
Class
name
RCREADY
Input
Output Controller power ON
ready
ATEXTMD
Input
Output Remote mode output
TEACHMD
Input
Output Teaching mode output This output indicates that the controller mode
ATTOPMD
Input
Output Automatic mode output This output indicates that the controller mode
IOENA
Input
Operation rights input
signal
Output Operation rights output
signal
START
Input
Start input
(Operation
right
required)
Output Operating output
Table 6-6
are available for the dedicated input/output signals. These are used by the
Page 83, "3.15 Operation of parameter screen"
Page 580, "6.5.2 Timing chart example"
Name
-
Outputs that the power has been turned ON
and that the external input signal can be
received.
-
This output indicates that the controller mode
is set to AUTOMATIC and remote operation
mode.
This signal must be turned ON before any con-
trol tasks using I/O signals can be performed.
-
is set to Teaching mode.
-
is set to AUTOMATIC and local operation
mode.
Sets the validity of the operation rights for the
external signal control.
Outputs the operation rights valid state for the
external signal control.
The operation right is given when the opera-
tion right input signal is ON, the controller
mode is set to AUTOMATIC, and there is no
other device that currently has the operation
right.
This input starts a program. To start a specific
program, select the program using the pro-
gram selection signal "PRGSEL" and numeri-
cal input "IODATA," and then input the start
signal. Note that when the parameter "PST" is
enabled, the system reads the program num-
ber from the numerical input (IODATA) and
starts the corresponding program (i.e., pro-
gram selection becomes no longer neces-
sary).
All task slots are executed during multitask
operation.
However, slots whose starting condition is set
to ALWAYS or ERROR via a parameter "SLT*"
will not be executed.
This output indicates that a program is being
executed. During multitask operation, this sig-
nal turns ON when at least one task slot is
operating.
However, slots whose starting condition is set
to ALWAYS or ERROR via a parameter "SLT*"
will not be executed.
for details on setting the parameters. If
Function
-
-
-
-
6External input/output functions
for time chart.
Factory shipment signal number.
Signal
Input, output
level
Note1)
CR7xx-Q
-1(No meaning),
-1(No meaning),
10001
-1
-1(No meaning),
-1(No meaning),
10002
-1
-1(No meaning),
-1(No meaning),
10003
-1
-1(No meaning),
-1(No meaning),
10004
-1
Level 10005,
5,
10005
3
Edge 10006,
3,
10006
0
Dedicated input/output 6-559