Parameter For Behavior Selection At The Error Occurrence On Dual System - Mitsubishi Electric CR750-Q Instruction Manual

Cr750/cr751/cr760 series
Hide thumbs Also See for CR750-Q:
Table of Contents

Advertisement

5Functions set with parameters

5.27 Parameter for behavior selection at the error occurrence on dual system

When the parameter CATEGORY is set for the error on dual system shown in
the [RESET] key input at the error occurrence on dual system can be selected.
Table 5-49:Target error list
Error number
H0039
H0046
H0051
The behavior of the [RESET] key input is set as shown in
Table 5-50:Action to the settings
Parameter settings
3 (Enable the error reset)
4 (Disable the error reset)
To reflect the settings of this parameter, you must turn the controller's power on again.
[Note]
The setting shown in this section is to select the behavior in a state without any abnormalities on the related
signal lines or wiring.
With the abnormalities, the errors shown above cannot be reset regardless of the parameter setting.
6-550 Parameter for behavior selection at the error occurrence on dual system
Content
Door Switch Signal line is faulty.
Faulty wiring (Enabling Device).
Wiring of the external emergency stop is abnormal.
Content
Error can be reset. (Default settings)
Error cannot be reset.
Table
Table
5-50.
5-49, the behavior of

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr750Cr751-qCr751-dCr760-dCr760-qCr750-d

Table of Contents