Installing The Control Unit - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

Controllers

4.2 Installing the control unit

4.2
Installing the control unit
Requirement
The installation site must fulfill the following requirements:
● Minimum clearance to surrounding parts 1 cm
● Even mounting surface
● Maximum distance from the power supply on account of the cable length:
– SIDOOR NT40 / SIDOOR Transformer: 1.5 m
● Maximum distance from the geared motor on account of the cable length:
– For SIDOOR M3, M4 and M5: 1.5 m
– With SIDOOR MDG180. MDG400. MDG400 NMS: 0.5 m / 1.5 m / 5 m / 7 m / 10 m /
– For SIDOOR MDG700 NMS: 5m / 10m / 15m / 20m
104
15 m / 20m
(Length depends on the MDG cable used)
WARNING
Risk of injury as a result of incorrect installation
Final application-specific requirements must be observed.
National Fire Protection Association (NFPA) Industry environment: Installation outside a
control cabinet only in horizontal mounting position.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB