Automatic Impulsedrive - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

SIDOOR functions
3.3 Extended functions
3.3.2

Automatic ImpulseDrive

Function description
The automatic ImpulseDrive system generates a drive order based on ImpulseDrive
detection.
If the ImpulseDrive analysis process detects an external impulse, the automatic
ImpulseDrive system generates a drive order with a normal drive profile. Both ImpulseDrive
detection output signals, IMPDRVVelo and IMPDRVIncr, are evaluated. If an enable
command is present, the automatic system initiates opening or closing with a normal drive
profile.
The automatic ImpulseDrive can only be used with an active enable. The enabling signal
(DCMD := 7) is an element of the DCMD signal (see Table A-16 DCMD signal (Page 287)).
Note
The configuration of ImpulseDrive detection directly affects the automatic ImpulseDrive
system.
Figure 3-5
64
Automatic ImpulseDrive system
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd420wSidoor atd410wSidoor atd430w

Table of Contents