Appendices
A.2 Profiles and adjustment ranges
Parameter
Reversal ramp open/close
Acceleration ramp close
Deceleration ramp close
Reversal ramp close/open
Idle torque open
Idle torque close
Peak torque close
Static force limit open
Static force limit close
Limit force end close
Static NDG-force (reduced)
Limit energy close
Limit energy open
Limit energy NDG
* Default profile (this profile is automatically loaded at the first commissioning)
A.2.5
SIDOOR MDG400 L / R
SIDOOR ATD4xxW
See Table A-43 Parameters and adjustment range SIDOOR M4 L / R apply for the SIDOOR
ATD4xxW controller (Page 301).
SIDOOR ATD4xxW
See Table A-43 Parameters and adjustment range SIDOOR M4 L / R apply for the SIDOOR
ATD4xxW controller (Page 301), SIDOOR ATD4xxW column.
302
Parameter ID
Unit
p3675
mm/s
p3676
mm/s
p3677
mm/s
p3678
mm/s
p3679
A
p3680
A
p3681
A
p3682
N
p3683
N
p3684
N
p3685
N
p1202
J
p1203
J
p1204
J
Profile 1*
1200
2
500
2
500
2
850
2
1
1
3
75
75
75
75
4
4
4
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Adjustment range
ATD4xxW
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
300 ... 1400
As of (V1.09): 250 ...
1400
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
0 ... 2.5
0 ... 2.5
0 ... 5
70 ... 360
70 ... 360
70 ... 360
70 ... 360
0 ... 100
0 ... 100
0 ... 100