Installation

Requirements
Observe the following installation rules:
● Minimum clearance to surrounding parts: 1 cm
● Even mounting surface
● The installation point should, as far as possible, be vibration-free. The permissible
climatic conditions (operating or storage and transport temperature) must be respected.
● Maximum distance from the power supply due to cable length:
– Connecting cable input line (network ⇔ NT40): 200 cm
– Connecting cable output line (NT40 ⇔ controller): 150 cm
● Operation outside the specified temperature range can lead to danger, malfunctions and
failure of the equipment.
● Protection class | according to EN 60950-1:2006
● The device must be installed in places that are accessible only to qualified personnel.
● In order to protect the modules from static electrical discharges, personnel must
discharge themselves electrostatically before opening control cabinets or terminal boxes.
● It is essential to ensure that the maximum temperature of 55 °C is not exceeded in the
mounting position. The device must not be exposed to direct sunlight.
Dangerous electrical voltage!
When electrical devices are used, certain parts of them have to carry dangerous voltages.
Failure to observe the operating instructions can therefore lead to serious injuries or
material damage.
Observe the operating instructions.
Procedure
Carry out the following steps in the given order:
1. Check that the operating data matches the values on the rating plate.
2. Mount the device with the aid of 4 (M6) screws and washers.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
WARNING
Power supply
6.1 SIDOOR NT40
219